The following events may occur during normal operation.

1. Protection of the air conditioner.

Compressor protection

The compressor cannot restart for 3 minutes after it stops. 

Anti-cold air 

The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one

of the following three situations and the set temperature has not been reached. 

A. When heating has just started.

B. Defrosting.

C. Low temperature heating.

Defrosting

The indoor or outdoor fan stops running when defrosting. 

Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and

humidity is high resulting in lower heating efficiency of the air conditioner.

During this condition air conditioner will stop heating operation periodically and start defrosting

automatically.

The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the

amount of frost buildup on the outdoor unit.

2. A white mist coming out from the indoor unit.

A white mist may generate due to a large temperature difference between air inlet and air outlet on

COOL mode in an indoor environment that has a high relative humidity.

A white mist may generate due to moisture generated from defrosting process when the air conditi-

oner restarts in HEAT mode operation after defrosting.

3. Low noise of the air conditioner.

You may hear a low hissing sound when the compressor is running or has just stopped running. This

sound is the sound of the refrigerant flowing or coming to a stop.

You can also hear a low "squeak" sound when the compressor is running or has just stopped run-

ning. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the

temperature is changing.

A sound may be heard due to louver restoring to its original position when power is first turned on. 

4. Dust is blown out from the indoor unit.

This is a normal condition when the air conditioner has not been used for a long time or during first

use of the unit.

5. A peculiar smell comes out from the indoor unit.

This is caused by the indoor unit giving off smells permeated from building material, from furniture,

or smoke.

man_TSC126_uk.qxd  10-05-2007  15:41  Pagina 117

Содержание TSC126

Страница 1: ...TSC126 2 6 5 3 4 FIN GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO MANUEL D UTILISATION K YTT OHJE OPERATING MANUAL 2 22 42 62 82 102 man_TSC126_de qxd 10 05 2007 15 27 Pagina 1...

Страница 2: ...used responsibly will give you many years of pleasure Please read these instructions for use first in order to ensure the maximum life span of your airconditioner On behalf of the manufacturer we pro...

Страница 3: ...MAINTENANCE 115 J OPERATION TIPS 117 K TROUBLESHOOTING TIPS 118 L GUARANTEE CONDITIONS 120 M TECHNICAL DATA 121 READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your...

Страница 4: ...ervice engineer or your recognised Tectro supplier Follow the instructions for use and maintenance as indicated in the user manual of this device Always remove the plug of the unit from the wall socke...

Страница 5: ...ing pipe drain hose not inclu ded l Air inlet side and rear m Air outlet The operation indicator lights flash rapidly five times per second when safety protection features come into operation G NOTE A...

Страница 6: ...t the following indoor and outdoor temperatures G CAUTION If air conditioner is used outside of the above conditions certain safety protection features may come into operation and cause the unit to fu...

Страница 7: ...to an angle until it remains fixed with a clicking sound 2 One press of the manual control button j will lead to the AUTO operation 3 Close the panel firmly to its original closed position G CAUTION...

Страница 8: ...is function is only can be used on COOL HEAT and AUTO mode and maintain the most comfortable temperature for you NOTE While the unit is running under SLEEP operation mode it would be cancelled if you...

Страница 9: ...r the digit display in the air conditioner press it again to activate it Not applicable to units without this function n TURBO Button Push this button on COOL mode the air conditioner goes into powerf...

Страница 10: ...er The OPERATION lamp on the display panel of the indoor unit lights The operating mode is AUTO The FAN SPEED is automatically controlled 4 Push the On off button again to stop the unit operation G NO...

Страница 11: ...ast set time for the starting operation and the signal Hr will be shown on the digital display area You are now ready to reset the time to START the operation 1 2 Push the Timer on button i again to s...

Страница 12: ...may be reduced Use TIMER ON button on the remote controller to select a time you want to start your air conditioner Do not put any object near air inlet or air outlet as the efficiency of the air con...

Страница 13: ...t right Adjust the vertical louver manually using the lever on the left or right side of the vertical louver arm depending on model When the air conditioner is in opera tion and the vertical louver is...

Страница 14: ...ive humidity The absolute humidity in the room will however be lowered depending on the amount of moisture produced in the room cooking people etc 1 1 1 1 G CAUTION The AIR DIRECTION and SWING buttons...

Страница 15: ...filter is completely dry and has no defects 6 Install the air freshening filter back into position 7 Insert the upper portion of air filter back into the unit taking care that the left and right edges...

Страница 16: ...eck that the wiring is not broken or disconnected Check that the air filter is installed Check if the air outlet or inlet is not blocked after the air conditioner has not been used for a long time G C...

Страница 17: ...white mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity A white mist may generate due to...

Страница 18: ...due to larger diffe rence between indoor and outdoor temperature If a comfortable temperature cannot be achieved by the air conditioner it is advised to use a supplementary heating device 9 Auto rest...

Страница 19: ...eceiver on the indoor unit The time you have set with timer is incorrect Wait or cancel timer setting Inappropriate temperature setting Set temperature correctly For detailed method please refer to op...

Страница 20: ...is valid only when you present the original dated purchase invoice and if no modifica tions have been made 6 The guarantee is invalid for damage caused by neglect or by actions that deviate from those...

Страница 21: ...ormance D COP 2 87 Dehumidifying capacity L 24h 24 Power consumption cooling kW 1 Power consumption heating kW 1 1 Power supply V Hz Ph 220 240 50 1 Current nom cooling heating A 4 6 4 7 Max Current A...

Страница 22: ...ntilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW...

Отзывы: