Tectro TSC126 Скачать руководство пользователя страница 12

3.  Set the starting & stopping time

3.1 Push the 

Timer on

button 

i

, the remote controller display will show 

ON TIMER

, the last set time for

Timer on

operation in hours will be shown on the Timer display area. You are now ready to readjust

the 

Timer on

to start the operation.

3.2 Push the 

Timer on

button 

i

again to set the time you want to start the operation.

3.3 Push the 

Timer off

button 

j

, the remote controller will show 

OFF TIMER

, the last set time for STOP

operation and the signal "Hr" will be shown on the Timer display area. You are now ready to set the

time to STOP operation.

3.4 Push the 

Timer off

button 

j

again to set the time you want to stop the operation.

3.5 After setting the TIMER, there will be half a second delay before the remote controller transmits the

signal to the Air Conditioner. Then, after approximately another 2 seconds, the signal "h" disappears

and the set temperature will re-appear on the digital display.

F

OPTIMAL OPERATION

To achieve optimal performance, please note the following:

Adjust the air flow direction correctly so that it is not directly directed to people.

Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive tem-

perature levels.

Close doors and windows otherwise the desired effect may be reduced.

Use TIMER ON button on the remote controller to select a time you want to start your air conditioner.

Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be redu-

ced and the air conditioner may stop running. Make sure there are no obstacles blocking the airflow.

The air stream must be allowed to reach the entire room unhindered. Also the air stream must be allo-

wed to reach the air conditioner unhindered.

Clean the air filter periodically, otherwise cooling or heating performance may be reduced. It is advi-

sed to clean the filters every two weeks.

Do not operate unit with horizontal louvre in closed position.

G

WARNING

• Keep the Remote Controller away from all liquids.

• Protect the Remote Controller from high temperatures and exposure to radiation.

• Keep the indoor receiver out of direct sunlight or the Air Conditioner may malfunction.

• Never mix new and old batteries. Never use different battery types (e.g. alkaline and

manganese dioxide) simultaneously.

G

NOTE!

• If the same time is set for both START and STOPPING settings, the stopping time will

automatically increase 0.5hr(the set time displays less than 10Hr) or one hour (the set time

displays 10Hr or more).

• To change the Timer on/off time, just press the corresponding TIMER button and reset the

time.

• The setting time is relative time. That is the time set is based on the delay of the current time.

4

112

man_TSC126_uk.qxd  10-05-2007  15:41  Pagina 112

Содержание TSC126

Страница 1: ...TSC126 2 6 5 3 4 FIN GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO MANUEL D UTILISATION K YTT OHJE OPERATING MANUAL 2 22 42 62 82 102 man_TSC126_de qxd 10 05 2007 15 27 Pagina 1...

Страница 2: ...used responsibly will give you many years of pleasure Please read these instructions for use first in order to ensure the maximum life span of your airconditioner On behalf of the manufacturer we pro...

Страница 3: ...MAINTENANCE 115 J OPERATION TIPS 117 K TROUBLESHOOTING TIPS 118 L GUARANTEE CONDITIONS 120 M TECHNICAL DATA 121 READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your...

Страница 4: ...ervice engineer or your recognised Tectro supplier Follow the instructions for use and maintenance as indicated in the user manual of this device Always remove the plug of the unit from the wall socke...

Страница 5: ...ing pipe drain hose not inclu ded l Air inlet side and rear m Air outlet The operation indicator lights flash rapidly five times per second when safety protection features come into operation G NOTE A...

Страница 6: ...t the following indoor and outdoor temperatures G CAUTION If air conditioner is used outside of the above conditions certain safety protection features may come into operation and cause the unit to fu...

Страница 7: ...to an angle until it remains fixed with a clicking sound 2 One press of the manual control button j will lead to the AUTO operation 3 Close the panel firmly to its original closed position G CAUTION...

Страница 8: ...is function is only can be used on COOL HEAT and AUTO mode and maintain the most comfortable temperature for you NOTE While the unit is running under SLEEP operation mode it would be cancelled if you...

Страница 9: ...r the digit display in the air conditioner press it again to activate it Not applicable to units without this function n TURBO Button Push this button on COOL mode the air conditioner goes into powerf...

Страница 10: ...er The OPERATION lamp on the display panel of the indoor unit lights The operating mode is AUTO The FAN SPEED is automatically controlled 4 Push the On off button again to stop the unit operation G NO...

Страница 11: ...ast set time for the starting operation and the signal Hr will be shown on the digital display area You are now ready to reset the time to START the operation 1 2 Push the Timer on button i again to s...

Страница 12: ...may be reduced Use TIMER ON button on the remote controller to select a time you want to start your air conditioner Do not put any object near air inlet or air outlet as the efficiency of the air con...

Страница 13: ...t right Adjust the vertical louver manually using the lever on the left or right side of the vertical louver arm depending on model When the air conditioner is in opera tion and the vertical louver is...

Страница 14: ...ive humidity The absolute humidity in the room will however be lowered depending on the amount of moisture produced in the room cooking people etc 1 1 1 1 G CAUTION The AIR DIRECTION and SWING buttons...

Страница 15: ...filter is completely dry and has no defects 6 Install the air freshening filter back into position 7 Insert the upper portion of air filter back into the unit taking care that the left and right edges...

Страница 16: ...eck that the wiring is not broken or disconnected Check that the air filter is installed Check if the air outlet or inlet is not blocked after the air conditioner has not been used for a long time G C...

Страница 17: ...white mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity A white mist may generate due to...

Страница 18: ...due to larger diffe rence between indoor and outdoor temperature If a comfortable temperature cannot be achieved by the air conditioner it is advised to use a supplementary heating device 9 Auto rest...

Страница 19: ...eceiver on the indoor unit The time you have set with timer is incorrect Wait or cancel timer setting Inappropriate temperature setting Set temperature correctly For detailed method please refer to op...

Страница 20: ...is valid only when you present the original dated purchase invoice and if no modifica tions have been made 6 The guarantee is invalid for damage caused by neglect or by actions that deviate from those...

Страница 21: ...ormance D COP 2 87 Dehumidifying capacity L 24h 24 Power consumption cooling kW 1 Power consumption heating kW 1 1 Power supply V Hz Ph 220 240 50 1 Current nom cooling heating A 4 6 4 7 Max Current A...

Страница 22: ...ntilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW...

Отзывы: