COOL, HEAT, and FAN ONLY Operation

1.

If the AUTO mode is not comfortable, you may manually override the settings by using COOL, DRY,

HEAT (HEAT PUMP units only), or FAN ONLY modes by pressing button 

b

.

2. Push 

the 

or 

button (

c

and 

d

) to set the desired room temperature. When in COOLING mode, the

most comfortable settings are 21ºC or above. When in HEATING mode, the most comfortable settings

are 28ºC or below.

3. Push 

the 

Fan

button 

e

to select the FAN mode of AUTO, HIGH, MED or LOW.

4. Push 

the 

On/off

button 

a

. The operation lamp lights and the air conditioner starts to operate per your

settings. Push the 

On/off

button 

a

again to stop this unit operation.

DRY Operation

1. Push the 

Mode

button 

b

to select DRY.

2. Push the 

or 

button (

c

and 

d

) to set the desired temperature from 21 C to 28 C.

3. Push the 

On/off

button 

a

. The operation lamp lights and the air conditioner starts to operate in the DRY

mode. Push the 

On/off

button 

a

again to stop this unit operation.

TIMER Operation

Push Timer on/off button (

i

and 

j

) to set the on and off times of the unit. The effective operation time

set by the remote controller for the timer function is limited to a period of between 0.5 and less than 24

hours.

1. 

To set the STARTING time.

1.1 Push the 

Timer on

button 

i

, then the remote controller display shows 

ON TIMER

, the last set time for

the starting operation and the signal "

Hr

" will be shown on the digital display area. You are now ready

to reset the time to START the operation.

1.2 Push the 

Timer on

button 

i

again to set desired unit start time.

1.3 After setting the 

Timer on

,there will be half a second delay before the remote controller transmits the

signal to the air conditioner. Then, after approximately another 2 seconds, the signal "h" disappears

and the set temperature will re-appear on the digital display.

2. 

To set the STOPPING time.

2.1 Push the 

Timer off

button 

j

and the remote controller display will show 

OFF TIMER

and the last set

time for the timer off operation in hours will be shown on the Timer display area. You are now ready

to reset the time of the STOP operation.

2.2 Push the 

Timer off

button 

j

again to set the time you want to stop the operation.

2.3 After setting the 

Timer off

, there will be half a second delay before the remote controller transmits

the signal to the air conditioner. Then, after approximately another 2 seconds, the signal "h" disappe-

ars and the set temperature will re-appear on the digital display.

G

NOTE!

Due to the difference of the set temperature of the unit and the actual indoor temperature, the

Air Conditioner when in DRY mode will automatically operate many times without running the

COOL and FAN mode.

G

NOTE!

The FAN ONLY mode cannot be used to control the temperature. In this mode, only steps 1, 3 and

4 are applicable.

man_TSC126_uk.qxd  10-05-2007  15:41  Pagina 111

Содержание TSC126

Страница 1: ...TSC126 2 6 5 3 4 FIN GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO MANUEL D UTILISATION K YTT OHJE OPERATING MANUAL 2 22 42 62 82 102 man_TSC126_de qxd 10 05 2007 15 27 Pagina 1...

Страница 2: ...used responsibly will give you many years of pleasure Please read these instructions for use first in order to ensure the maximum life span of your airconditioner On behalf of the manufacturer we pro...

Страница 3: ...MAINTENANCE 115 J OPERATION TIPS 117 K TROUBLESHOOTING TIPS 118 L GUARANTEE CONDITIONS 120 M TECHNICAL DATA 121 READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your...

Страница 4: ...ervice engineer or your recognised Tectro supplier Follow the instructions for use and maintenance as indicated in the user manual of this device Always remove the plug of the unit from the wall socke...

Страница 5: ...ing pipe drain hose not inclu ded l Air inlet side and rear m Air outlet The operation indicator lights flash rapidly five times per second when safety protection features come into operation G NOTE A...

Страница 6: ...t the following indoor and outdoor temperatures G CAUTION If air conditioner is used outside of the above conditions certain safety protection features may come into operation and cause the unit to fu...

Страница 7: ...to an angle until it remains fixed with a clicking sound 2 One press of the manual control button j will lead to the AUTO operation 3 Close the panel firmly to its original closed position G CAUTION...

Страница 8: ...is function is only can be used on COOL HEAT and AUTO mode and maintain the most comfortable temperature for you NOTE While the unit is running under SLEEP operation mode it would be cancelled if you...

Страница 9: ...r the digit display in the air conditioner press it again to activate it Not applicable to units without this function n TURBO Button Push this button on COOL mode the air conditioner goes into powerf...

Страница 10: ...er The OPERATION lamp on the display panel of the indoor unit lights The operating mode is AUTO The FAN SPEED is automatically controlled 4 Push the On off button again to stop the unit operation G NO...

Страница 11: ...ast set time for the starting operation and the signal Hr will be shown on the digital display area You are now ready to reset the time to START the operation 1 2 Push the Timer on button i again to s...

Страница 12: ...may be reduced Use TIMER ON button on the remote controller to select a time you want to start your air conditioner Do not put any object near air inlet or air outlet as the efficiency of the air con...

Страница 13: ...t right Adjust the vertical louver manually using the lever on the left or right side of the vertical louver arm depending on model When the air conditioner is in opera tion and the vertical louver is...

Страница 14: ...ive humidity The absolute humidity in the room will however be lowered depending on the amount of moisture produced in the room cooking people etc 1 1 1 1 G CAUTION The AIR DIRECTION and SWING buttons...

Страница 15: ...filter is completely dry and has no defects 6 Install the air freshening filter back into position 7 Insert the upper portion of air filter back into the unit taking care that the left and right edges...

Страница 16: ...eck that the wiring is not broken or disconnected Check that the air filter is installed Check if the air outlet or inlet is not blocked after the air conditioner has not been used for a long time G C...

Страница 17: ...white mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity A white mist may generate due to...

Страница 18: ...due to larger diffe rence between indoor and outdoor temperature If a comfortable temperature cannot be achieved by the air conditioner it is advised to use a supplementary heating device 9 Auto rest...

Страница 19: ...eceiver on the indoor unit The time you have set with timer is incorrect Wait or cancel timer setting Inappropriate temperature setting Set temperature correctly For detailed method please refer to op...

Страница 20: ...is valid only when you present the original dated purchase invoice and if no modifica tions have been made 6 The guarantee is invalid for damage caused by neglect or by actions that deviate from those...

Страница 21: ...ormance D COP 2 87 Dehumidifying capacity L 24h 24 Power consumption cooling kW 1 Power consumption heating kW 1 1 Power supply V Hz Ph 220 240 50 1 Current nom cooling heating A 4 6 4 7 Max Current A...

Страница 22: ...ntilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW...

Отзывы: