![Tecson Tankspion-IoT Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/tecson/tankspion-iot/tankspion-iot_installation-manual_1072917010.webp)
V2.1 | 11-2022 Installation and Commisioning of Tankspion-IoT devices
10
Technical Data
Power supply:
3,6V Lithium battery 14Ah Item no.: 13901
D cell ER34615M
Measurement Input:
4-20mA; U
b
ca 15V
Meas. resolution:
12 Bit
Meas. deviation:
< 1%
Dimensions H x B x T:
[with flanges]:
PRO / GPS versions:
115x65x55 [mm]
145x65x55 [mm]
155x130x60 [mm]
Housing: ABS, protection class: IP65
with pressure compensation element
Antenna:
Tankspion-IoT: intern.
PRO: external
GPS: external
Frequency range: 824~960/1710~2170MHz
824~960/1710~2170MHz
GPS: 1575.42±3MHz
Transmission type:
NB-IoT is based on LTE Cat M1 and NB-IoT with GSM / GPRS fallback.
SIM card format:
3FF micro SIM card, included in delivery.
Data reporting target:
OilView server (IoT Cloud)
Standard Measuring Probe
Type:
Voltage:
TDS-61-250-P6
Ub from measurement input: ~15V DC
Protection class of probe:
IP68 according to IEC 529
Materials:
V4A; POM; FPM; PUR
Cable length 5-6 m,
orderable with 5 m extra
length each
Installation position:
Lying horizontally, or hanging vertically with contact to the ground
Temperature range:
Fluid tempearture: 0 °C to +45 °C, higher on request
Measuring range:
250mbar, 25kPa (2,5m water column or 2,9m oil column)
Screw-in connnection:
1 inch and 1.5 inch included
Measuring Fluids:
Compatible and suitable measuring fluids at ambient temperature:
Heating oil EL
according to DIN 51603-1
Diesel fuel DK
according to DIN EN 590
Biodiesel
according to DIN EN 14214
Water
Urea solution
e.g. AdBlue according to DIN 70700
Gasoline
with flash point < 55°C
Only after consultation,
at least with ATEC measuring probe and ATEX barrier
Various other
After consultation!