V6.x // 06-2016
Setup and Operation
P. 7
Device setup and programming
Press [Enter] to open the menu. The menu offers the menu steps 1
… 7.
Menu steps 9
… 24 offer special advanced options.
Only one level sensor can be connected to the instruments
e-litro net
/
e-litro gsm
.
Using the
e-litro
displaying device either one or two LITRO-Sensors can be connected.
Two sensors =
duo
-solution.
Shape and size of the tank or container has to be entered only once.
This applies for both the
e-litro
and the
e-litro duo.
Press [ + ] to navigate to a particular menu item. Enter the parameterization of a particular
menu item and confirm the selected the value by pressing [Enter].
Input function:
Menu functions
Description
Device type
4
0. Exit
Entering the programming mode.
Proceed with [+].
Also leaving the programming with [Enter] at the Exit item.
all
1. Measuring probe
For
secu4
1. Tank quantity
Setting up the measuring range of the level sensor:
The LITRO-Sensor is preset to 250mbar.
Measuring range:
max. oil tank height: water column:
250 mbar
( 3.00 m )
( 2.50 m )
If a different level sensor to the LITRO-Sensor is used, the
respective measuring range has to be entered in mbar.
If
‘by calibration’
is displayed, a calibration was done via
menu item 10
/
11
‘Trim height/Trim volume’.
Battery tanks:
n
n = quantity (1 to 4) of connected tanks
(all)
Do not enter
the level or
tank height
here.
Enter mbar
referring to
sensor label.
only for secu4
2. Liquid
Selection of measuring liquid (specific weight of the liquid):
Heating oil
, water, diesel oil, bio diesel oil, rapeseed oil, mo-
tor oil, lubrication oil, waste oil, other liquids after consultation.
.
Do not use AdBlue, palm oil, A1-media (petrol).
Or enter the
‘Density value’ in xxx kg / m
3
. Use [+] [-].
If the density value of the liquid is unknown calibrate the
device via menu item
‘10.Trim height’
If
‘by calibration’ is displayed, a calibration was done via
menu item 10
/
11
‘Trim height/Trim volume’. In that case the
parameter
‘Liquid’ (resp. density) is not relevant.
all