Setup and Operation
V6.x // 06-2016
8. Exit
or
8. PExit
secu4 password
activation:
Press [Enter] to leave the setup mode (parameterization).
For the
secu4
the
password protection
needs to be
activated with
‘YES’ if the relay disruptor function for the
overfill safety is used.
During the activation the password will be shown once.
The password is fixed
, meaning it is not changeable but
only activatable/deactivatable.
The qualified technician should note down the password and
store it appropriately.
If the password is lost please contact TECSON.
Therefore please have the serial number of the device ready!
not for secu4
for secu4
loss of
password
Menu item 9
– 24
see ff.
Steps 9
– 24 contain
special settings
which usually will not
be needed.
all
After entering/setup of step 1 to 7 the standard programming is completed.
By confirming the
‘Exit’-step the device automatically returns to the usual displaying mode and
the present tank content is shown.
Mount the device cover after completing the initial setup!
Programming examples
Example 1
Cellar welded heating oil tank for 6000 L of heating oil, linear steel tank.
Interior height 165 cm, (filling level: 125 cm), LITRO-level probe 0 -
250 mbar
.
Device
e-litro
:
Menu item
1. Measuring probe
2. Liquid
3. Tank shape
4. Tank volume
5. Tank height
5b. Filling Limit
6. Display
7. Relay
8. Exit [Enter]
Setting / Selection
250 mbar
Heating oil
Linear
6000 liter
165.0 cm
95%
Fil Level
OFF
Displaying mode => ... 4550 l ... 76 %