background image

Operating manual 
E3907 
 

www.tecsis.de 

BE 984 i 

 
 

1. Safety notes 

 

1.1 General references 

 
The enclosed operating instruction is intended for technically qualified personnel who has corresponding knowledge 
in the field of measurement and industrial process & control technology. 
The precise information about all safety notes contained in this operation manual and warnings, as well as its  
technical implementation are precondition for the safe installation, the initiation, the secure operation and the 
maintenance of tecsis  devices. For this purpose it is absolutely necessary that all measures are carried out by 
qualified personnel. All persons concerned with the project planning, installation and service of tecsis devices, must 
be familiar to the security concepts in automatic control and should be qualified in this sense. 
For clarity reasons, the enclosed operating instruction cannot represent complete details in all conceivable cases of 
applications for the handling of tecsis devices. Further, we cannot consider the entire types of installation, handling 
and maintenance. If you wish further information or if special problems occur, which were not ,or not at length 
represented in this operating instruction, contact us, please.. 
 
The oblivion of the safety notes can and will lead to material damages, body injuries and death. 
Tecsis devices may only be operated in accordance with the applications described in this operation 
manual. Built-in devices may only be operated in appropriate installations.   
 
With the connection and the initiation of the device, the customer accepts the general sale and delivery conditions 
of  tecsis GmbH. Further, he accepts eventually incomplete operation manuals. The information described is 
without guarantee. Errors and changes are reserved.             
 
 
Intended Purpose, Improper Usage 
 
A tecsis device is used for displaying, processing and controlling or regulation of processes. It shall not be used as 
the only tool for the prevention of dangerous states to machines and plants. Machines and plants must be 
constructed in such a  way, that erroneous states cannot lead to a dangerous situation for the staff (e.g. by 
independent limit switches, mechanical locking devices). It must be guaranteed in particular that device-operating 
errors, its malfunction or it’s breakdown do not lead to great property damages or danger for the staff. 
Consequently, the device then can be used to prevent the machine or the technical installations from error 
conditions.  
It is also important that the use of devices does not endanger precautions for the safety of technical installations. 
Emergency-off settings must remain effective in all operation modes. 
 
 
Installation Notes 
 
tecsis devices must be installed and connected by compliance with the relevant DIN- and VDE-norms. They must 
be installed in such manner that an unintentional use is sufficiently excluded. The corresponding hardware and 
software safety precautions are to be observed in such manner that an interruption of the supply and signal cables 
cannot lead to an undefined or dangerous state. Supply and signal cables must be installed in such way, that 
disturbing signals (e.g. inductive or capacitive intersperses) will not cause derogations to the function of tecsis 
devices. 
 
 
Disturbance, Maintenance and Repair Notes 
 
The devices do not contain parts which can be maintained on the customer side. Repairs shall be carried out by 
tecsis exclusively. 
If assuming that a safe operation of the device is not possible anymore, it must be closed down and protected 
against unintentional handling immediately. This, in particular, applies: 
 
- If the device shows visible damages 
- If the device is no longer operative    

Содержание E3907

Страница 1: ...Force Pressure Temperature Switch Service Operating manual E3907 Universal handheld measuring device with datalogger BD 984 i 02 2013...

Страница 2: ...y 63073 Offenbach am Main Valid for E3907 handheld measuring device with datalogger Copyright 2006 2015 tecsis GmbH Offenbach Germany Reproduction prohibited Reproduction in whole or in part only with...

Страница 3: ...interface 11 4 6 1 Transfer rate specification RS232 V 24 USB 11 4 6 2 Operation via the serial interface 11 4 6 3 Handling with serial interface USB 14 4 6 4 Operation and function principle of the E...

Страница 4: ...Operating manual E3907 BE 984 i www tecsis de...

Страница 5: ...arantee Errors and changes are reserved Intended Purpose Improper Usage A tecsis device is used for displaying processing and controlling or regulation of processes It shall not be used as the only to...

Страница 6: ...take responsibility for that residual risks and to keep them as low as possible The relevant regulations and laws must be observed Residual risks or dangers associated with the measurement device shou...

Страница 7: ...s The device may only be used by qualified personnel according to the technical data in connection with the special safety rules and regulations 1 8 Technical changes The product may not be changed co...

Страница 8: ...An assignment of sensors to the corresponding parameter set is documented on the rear of the device 3 2 Power supply Mains operation Power supply 6V DC min 1 8A Fuse Self reset able fuse 1 5A Under Ov...

Страница 9: ...evice from moisture condensation rain snow Protect the device from direct sunlight Protect the device from dust and dirt Protect the device from high or excessive ambient temperature Protect the devic...

Страница 10: ...nu ESC Switch off the device Exit one step back in the menu Scroll up Scroll down USB USB Socket for USB Connector Type B RS232 RS232 Socket for 3 5mm jack 3pol front GND middle RxD outside TxD 6V DC...

Страница 11: ...Operating manual E3907 www tecsis de BE 984 i 7...

Страница 12: ...Operating manual E3907 8 BE 984 i www tecsis de 4 2 Switching on the device Press the ENTER button to switch on the device 4 3 Menu description 4 3 1 Brief handling overview E3907...

Страница 13: ...w many measurements an average value is accumulated Applicable at e g vibrations control oscillations 2 5 PASS Password query After entering the password 9373 it is possible to enter menu 3 CALIB Ther...

Страница 14: ...appear on the LCD Press ENTER again and the time can be adjusted With PLUS and MINUS the hours can be adjusted After ENTER the minutes can be adjusted with PLUS and MINUS With ENTER the selected time...

Страница 15: ...uring every keystroke on ENTER while measuring For data logging adjust operating mode in the logger mode e g choose AUTO and interval time e g 10 sec and change to measuring mode A measured value with...

Страница 16: ...Out datalogger B 0x42 Delete datalogger C 0x43 Read Out current sensor parameter D 0x44 Read Out status E 0x45 Read Out complete status g 0x67 Change protocol setup k 0x6B ENTER l 0x6C PLUS m 0x6D MI...

Страница 17: ...mA and 100 load mA Dec point 0xXXXX XXXX 000 _5000___ 001 _5 000__ 010 _50 00__ 011 _500 0__ 100 5 000___ 0 load 2Byte HEX value MSB LSB 100 load 2Byte HEX value MSB LSB 4 6 2 3 Read out status Status...

Страница 18: ...ol status 1Byte 0xXXXX XXXX binary coded 1 no closing character is sent 1 send CR LF 1 send CR 1 send LF 4 6 2 12 Calculation of the Checksum CS and the Weighted Checksum wCS The calculation takes pla...

Страница 19: ...starting time of the measurement the current sensor designation the final value of the measuring range the adjusted measuring rate and the logger mode e g AUTO 1ms are saved in the logger NOTE All pr...

Страница 20: ...ress key or and choose between 0 Load or Sensitivity 0 Load Relieve sensor from load or Sensitivity Enter the value fort the sensitivity in V Press Key or and choose between 100 Load or Sensitivity 10...

Страница 21: ...0mA short circuit protected Bridge resistance min 350 Ohm only full bride 4 or 6 conductor Sensitivity up to 3 3mV V other values on request 100 control via E3907 applied via control input 4 8 2 Conne...

Страница 22: ...measures before installation Attention The information for the voltage supply in section 5 2 must be respected Cable connections Attention Never connect voltage supply on non used pins 5 3 Normal ope...

Страница 23: ...k the plug connections Repair Notation The products contain no parts that need to be or that can be serviced by the user himself Repairs may only be carried out by the tecsis GmbH If it can be assumed...

Страница 24: ...tecsis GmbH Carl Legien Stra e 40 44 63073 Offenbach am Main Germany Phone 49 69 5806 0 Fax 49 69 5806 7788 E Mail force tecsis de Internet www tecsis de...