4.6.2.2 Read-Out of current sensor parameters:
Sensor designation
8Byte
ASCII
Display final value
2Byte
packed BCD-figure
Unit
3Byte
ASCII
Sensor type and digit
1Byte
0xAB: A ... Sensor type, B ... digit of the dec. point (binary coded)
Sensor type:
0xXXXX XXXX
||||
0000 ... active with calibration control 0%load and 100% load calibration
0001 ... active without calibration control 0%load and 100% load calibration
0010 ... active without calibration control 0%load calibration and edit 100%load V
0011 ... active without calibration control edit 0%load V and 100%load V
0100 ... passive with calibration control 0%load and 100% load calibration
0101 ... passive without calibration control 0%load and 100% load calibration
0110 ... passive without calibration control 0%load calibration and edit 100% load in mV/V
0111 ... passive without calibration control edit 0%load and 100% load in mV/V
1000 ... current 0%load and 100% load calibration
1001 ... current 0%load calibration and edit 100%load in mA
1010 ... current edit 0%load mA and 100%load mA
Dec. point:
0xXXXX XXXX
||||
|000 ... _5000___
|001 ... _5,000__
|010 ... _50,00__
|011 ... _500,0__
|100 ... 5,000___
0%load
2Byte
HEX-value (MSB/LSB)
100% load
2Byte
HEX- value (MSB/LSB)
4.6.2.3 Read out status:
Status 2Byte, general error condition of the E3907
4.6.2.4 Read-Out complete status:
Status
2Byte
general error condition of the GM 80
Measuring rate
1Byte
0x01 … 1000/sec
0x02 … 100/sec
0x03 ... 10/sec
0x04 ... 1/sec
Average value
1Byte
0x01 ... x/1
0x02 ... x/2
0x04 ... x/4
0x08 ... x/8
0x10 ... x/16
0x20 ... x/32
SCI_MODE
1Byte
0x00 ... interface off
0x04 … hand mode
0x08 … automatic mode
0x0C … trigger mode
SCI_MODE_DELAY
1Byte
0x02 …10ms
0x03 … 100ms
0x04 … 1s
0x05 … 10s
0x06 ... 1min
0x07 ... 10min
0x08 ... 1h
LOGGMODE
1Byte
0x00 ... logger off
0x04 ... hand mode
0x08 ... automatic mode
0x0C ... graph mode
0x10 ... screen mode
LOGGMODE_DELAY
1Byte
0x01 … 1ms
0x02 …10ms
0x03 … 100ms
0x04 … 1s
0x05 … 10s
0x06 ... 1min
0x07 ... 10min
0x08 ... 1h
Language
1Byte
0x00 ... GERMAN
0x02 ... ENGLISH
0x04 ... FRENCH
0x06 ... SPANISH
Protocol status
1Byte
0xXXXX XXXX (binary coded)
|||| ||||
|||| |||1 ... do not send conclusion character
|||| ||1 ... send CR/LF
|||| |1 ... send CR
|||| 1 ... send LF
4.6.2.5 Read time
The writing is identically with the data block for receipt of time, however, the data block for writing is protected with a