If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it 
on immediately. The arising condensation water might damage your device. Leave the device switched off 
until it has reached room temperature. 

 

Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C 
connection cable or on the casing, do not take the device into operation and immediately consult your local 
dealer. 

 

This  device  falls  under  protection-class  I.  The  power  plug  must  only  be  plugged  into  a  protection  class  I 
outlet.  The  voltage  and  frequency must  exactly  be  the  same  as  stated  on  the  device.  Wrong  voltages  or 
power outlets can lead to the destruction of the device and to mortal electrical shock. 

 

Always plug in the power plug last. The power plug must always be inserted without force. Make sure that 
the plug is tightly connected with the outlet. 

 

Never let  the  power-cord come into contact with  other cables!  Handle the power-cord and  all  connections 
with  the  mains  with  particular  caution!  Never  touch  them  with  wet  hands,  as  this  could  lead  to  mortal 
electrical shock. 

 

Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next 
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock. 

 

The cable insert or the female part in the  device must never be strained. There must always be sufficient 
cable to the device. Otherwise, the cable may be damaged which may lead to mortal damage. 

 

Make  sure  that  the  power-cord  is  never  crimped  or  damaged  by  sharp  edges.  Check  the  device  and  the 
power-cord from time to time. 

 

If  extension  cords  are  used,  make  sure  that  the  core  diameter  is  sufficient  for  the  required  power 
consumption of  the  device.  All  warnings concerning the  power  cords  are  also  valid  for  possible  extension 
cords. 

 

Always  disconnect  from  the  mains,  when  the  device  is  not  in  use  or  before  cleaning  it.  Only  handle  the 
power-cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can 
be damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the 
device must be disconnected via the mains. 

 

If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be 
cleaned  with  a  dry  cloth.  Dust  can  reduce  the  insulation  which  may  lead  to  mortal  electrical  shock.  More 
severe dirt in and at the device should only be removed by a specialist. 

 

There  must  never  enter  any  liquid  into  power  outlets,  extension  cords  or  any  holes  in  the  housing  of  the 
device. If you suppose that also a minimal amount of liquid may have entered the device, it must immediately 
be  disconnected.  This  is  also  valid,  if  the  device  was  exposed  to  high  humidity.  Also  if  the  device  is  still 
running,  the  device  must  be  checked  by  a  specialist  if  the  liquid  has  reduced  any  insulation.  Reduced 
insulation can cause mortal electrical shock. 

 

There must never be any objects entering into the device. This is especially valid for metal parts. If any metal 
parts like staples or coarse metal chips enter into the device, the device must be taken out of operation and 
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries. 
 
 

HEALTH HAZARD!

 

Never  look directly  into the light source,  as sensitive  persons  may suffer  an 
epileptic  shock  (especially  meant  for epileptics)!

 

 
 
 
Keep away children and amateurs! 
Never leave this device running unattended. 
 
 

Содержание Ion 132B

Страница 1: ...USER MANUAL Read the user manual before turning on the product...

Страница 2: ...re device 2 User manual 3 Omega holder with quick lock fastener 4 DMX cable 3m 5 PowerCon power supply cable 1 5m 6 Safety rope SAFETY INSTRUCTIONS This device has left our factory in absolutely perfe...

Страница 3: ...me If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings concerning the power cords are also valid for possible exten...

Страница 4: ...heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunder...

Страница 5: ...5 damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock crash etc...

Страница 6: ...Features DMX channels 13 15 16 Color wheel 14 1 colors Static gobo wheel 17 1 gobos Motorized focus Full range 0 100 dimmer Various strobe 8 facets rotating Effect wheel RDM function to change DMX ad...

Страница 7: ...ctive lens 2 Arm 3 Base 4 Handle 5 Wireless indicator 6 Display 7 Microphone 8 Left button 9 Down buttom 10 Enter button 11 Up button 12 Right button 13 3 PIN DMX input socket 14 3 PIN DMX output sock...

Страница 8: ...anded Please follow the lamp manufacturer s notes Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non obs...

Страница 9: ...gging or servicing the fixture staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety r...

Страница 10: ...tc within a distance of min 0 5 m CAUTION Use an appropriate clamp to rig the fixture on the truss Follow the instructions mentioned at the bottom of the base Make sure that the device is fixed proper...

Страница 11: ...um drop distance must never exceed 20 cm A safety bond which already hold the strain of a crash or which is defective must not be used again DANGER TO LIFE Before taking into operation for the first t...

Страница 12: ...with another Occupation of the XLR connection If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first fixture in the...

Страница 13: ...ter you connected the effect to the mains the fixture starts running During the reset the motors are trimmed and the device is ready for use afterwards Stand Alone operation In the Stand Alone mode th...

Страница 14: ...ol Channe l name function Min DMX Max DMX St Ex1 Ex 2 1 1 1 Pan Pan Coarse 0 255 2 2 Pan fine Pan Fine 0 255 2 3 3 Tilt Tilt Coarse 0 255 4 4 Tilt fine Tilt Fine 0 255 3 5 5 Movment Speed fastest to S...

Страница 15: ...Position 13 204 220 Position 14 221 237 Position 15 238 255 Forward Spin Stop to fastest 0 255 Reverse Spin Stop to fastest 0 255 Continuous Positioning from 0 360 degrees 0 255 9 11 12 Gobo Function...

Страница 16: ...3 Display On 64 71 Lamp Off 72 79 Lamp On 80 87 Hibernation 88 95 TBD 96 255 Control Board The Control Board offers several features you can simply set the starting address run the pre programmed prog...

Страница 17: ...Software Ver 1U01 V1 0 00 2U01 V1 0 00 Version of each IC Set Reset All Pan Tilt Colors Gobos Shutter Others Reset all Reset Pan Tilt Reset Colors Reset Gobos Reset Shutter Reset Others Movment Pan R...

Страница 18: ...Chase Chase Part 1 Chase Part 2 Chase Part 3 Chase 1 8 Chase 1 Chase 1 8 Chase 2 Chase 1 8 Chase 3 Select and run auto program Edit Chase Chase 1 Chase 8 Chase Test Step 01 Step 64 SCxxx SCxxx Test Be...

Страница 19: ...sius degree Fahrenheit Fan speed With this function you can display the current fan speed The display shows XXXX X stands for Hz Initial status With this function you can display with which value the...

Страница 20: ...ed after a predefined period of time of no DMX activity In standby mode the lamp LEDs and all motors will power down if no DMX signal is sent to the fixture for a period of e g 15 minutes can be user...

Страница 21: ...of RDM parameters depend on the optional RDM controller being used RDM Parameter ID s Slot 21 22 Value Category _Network Management DISC_UNIQUE_BRANCH 0x0001 DISC_MUTE 0x0002 DISC_UN_MUTE 0x0003 Categ...

Страница 22: ...different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop The Slave uni...

Страница 23: ...ess the Enter button to confirm Press Up or Down to select the desired value Press the Enter button to confirm Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 and Progra...

Страница 24: ...and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts like axles eyes and others must not sh...

Страница 25: ...rther questions please contact your dealer TECHNICAL SPECIFICATIONS Power supply 100 240 V AC 50 60 Hz Power consumption 190 W DMX control channels 13 15 16 DMX512 connection 3 pin XLR Sound control v...

Отзывы: