TECshow Ion 132B Скачать руководство пользователя страница 17

   

   

17   

DMX   Control   

ON/OFF

   

DMX   control   or   not   

Max   
Temperature

   

80

~

139

,

   120

    /176~282

,

   248

   

Lamp   off   if   
temperature   
continuously   over   
for   5   minutes   

Lamp   Adjust

   

PAN……

   

Adjust   value   of   
channel   

In

fo

rm

at

io

n   

Time   Info.   

Current                        XXXX(Hours)   
Fixture   Life        XXXX(Hours)   

Fixture   boot   time   
Fixture   total   run   
time   

Lamp   Info.   

Voltage   
Current   
Power   

HID   Lamp   
Information   

Temperature   

Near   Lamp   Temp        (depends   on   fixture)   

Temperature   
Sensors   

Fans   Speed   

Near   Lamp   Fan        (depends   on   fixture)   

Fan   speed   Sensors   

Channel   Value   

PAN……   

Display   value   of   
channel   

Error   Message   

Pan,Tilt……   

Error   channels   

Fixture   Model   

xxxxxxxxxxxx   

Display   model   brand   
and   model   

Software   Ver   

1U01        V1.0.00   
2U01        V1.0.00   
:

   

Version   of   each   IC   

Se

t   

Reset   

All   
Pan&Tilt   
Colors   
Gobos   
Shutter

   

Others   

Reset   all       
Reset   Pan&Tilt   
Reset   Colors   
Reset

   

Gobos   

Reset

   

Shutter

   

Reset   Others

 

Movment   

Pan   Reverse

   

Tilt   Reverse

   

Pan   Degree

   

Encoders

   

Pan/Tilt   Mode

   

ON/OFF   
ON/OFF   
630/540   
ON/OFF   
Stand/Smooth   

Pan   Reverse   
Tilt   Reverse   
Choose   Pan   Degree   
Encoder   wheel   
on/off   
Choose   pan/tilt   
mode   

UI   Set   

Mic   Sens.

 

   

No   Signal

   

Temperature.   C/F

 

Fans   Mode

   

Hibernation

   

Backlight

   

Flip   Display

 

Display   Bright

 

Brand   Show

   

Key   Lock

   

0~99%,60%   
Close/Hold/Auto/Music   
Fahrenheit/Celsius   
Auto   Speed   /High   Speed   

OFF,   01M~99M

15M   

02~60m   02m   

ON/OFF   

00~31   10   
ON/OFF   

ON/OFF   

Sensitivity   of   Mic   
Mode   when   no   
signal   
Temperature   at   

/

   

Fans   mode   
Sleeping   mode   

Show   backlight   time

 

Display   180

°

reverse   
Display   Brightness

 

Show   brand   or   not   
Key   lock   on/off

 

Содержание Ion 132B

Страница 1: ...USER MANUAL Read the user manual before turning on the product...

Страница 2: ...re device 2 User manual 3 Omega holder with quick lock fastener 4 DMX cable 3m 5 PowerCon power supply cable 1 5m 6 Safety rope SAFETY INSTRUCTIONS This device has left our factory in absolutely perfe...

Страница 3: ...me If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings concerning the power cords are also valid for possible exten...

Страница 4: ...heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunder...

Страница 5: ...5 damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock crash etc...

Страница 6: ...Features DMX channels 13 15 16 Color wheel 14 1 colors Static gobo wheel 17 1 gobos Motorized focus Full range 0 100 dimmer Various strobe 8 facets rotating Effect wheel RDM function to change DMX ad...

Страница 7: ...ctive lens 2 Arm 3 Base 4 Handle 5 Wireless indicator 6 Display 7 Microphone 8 Left button 9 Down buttom 10 Enter button 11 Up button 12 Right button 13 3 PIN DMX input socket 14 3 PIN DMX output sock...

Страница 8: ...anded Please follow the lamp manufacturer s notes Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non obs...

Страница 9: ...gging or servicing the fixture staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety r...

Страница 10: ...tc within a distance of min 0 5 m CAUTION Use an appropriate clamp to rig the fixture on the truss Follow the instructions mentioned at the bottom of the base Make sure that the device is fixed proper...

Страница 11: ...um drop distance must never exceed 20 cm A safety bond which already hold the strain of a crash or which is defective must not be used again DANGER TO LIFE Before taking into operation for the first t...

Страница 12: ...with another Occupation of the XLR connection If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first fixture in the...

Страница 13: ...ter you connected the effect to the mains the fixture starts running During the reset the motors are trimmed and the device is ready for use afterwards Stand Alone operation In the Stand Alone mode th...

Страница 14: ...ol Channe l name function Min DMX Max DMX St Ex1 Ex 2 1 1 1 Pan Pan Coarse 0 255 2 2 Pan fine Pan Fine 0 255 2 3 3 Tilt Tilt Coarse 0 255 4 4 Tilt fine Tilt Fine 0 255 3 5 5 Movment Speed fastest to S...

Страница 15: ...Position 13 204 220 Position 14 221 237 Position 15 238 255 Forward Spin Stop to fastest 0 255 Reverse Spin Stop to fastest 0 255 Continuous Positioning from 0 360 degrees 0 255 9 11 12 Gobo Function...

Страница 16: ...3 Display On 64 71 Lamp Off 72 79 Lamp On 80 87 Hibernation 88 95 TBD 96 255 Control Board The Control Board offers several features you can simply set the starting address run the pre programmed prog...

Страница 17: ...Software Ver 1U01 V1 0 00 2U01 V1 0 00 Version of each IC Set Reset All Pan Tilt Colors Gobos Shutter Others Reset all Reset Pan Tilt Reset Colors Reset Gobos Reset Shutter Reset Others Movment Pan R...

Страница 18: ...Chase Chase Part 1 Chase Part 2 Chase Part 3 Chase 1 8 Chase 1 Chase 1 8 Chase 2 Chase 1 8 Chase 3 Select and run auto program Edit Chase Chase 1 Chase 8 Chase Test Step 01 Step 64 SCxxx SCxxx Test Be...

Страница 19: ...sius degree Fahrenheit Fan speed With this function you can display the current fan speed The display shows XXXX X stands for Hz Initial status With this function you can display with which value the...

Страница 20: ...ed after a predefined period of time of no DMX activity In standby mode the lamp LEDs and all motors will power down if no DMX signal is sent to the fixture for a period of e g 15 minutes can be user...

Страница 21: ...of RDM parameters depend on the optional RDM controller being used RDM Parameter ID s Slot 21 22 Value Category _Network Management DISC_UNIQUE_BRANCH 0x0001 DISC_MUTE 0x0002 DISC_UN_MUTE 0x0003 Categ...

Страница 22: ...different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop The Slave uni...

Страница 23: ...ess the Enter button to confirm Press Up or Down to select the desired value Press the Enter button to confirm Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 and Progra...

Страница 24: ...and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts like axles eyes and others must not sh...

Страница 25: ...rther questions please contact your dealer TECHNICAL SPECIFICATIONS Power supply 100 240 V AC 50 60 Hz Power consumption 190 W DMX control channels 13 15 16 DMX512 connection 3 pin XLR Sound control v...

Отзывы: