TECshow Ion 132B Скачать руководство пользователя страница 16

   

   

16   

Position 14 

182 

195 

Position 15 

196 

209 

Position 16 

210 

223 

Position 17 

224 

237 

Position 18 

238 

255 

Forward Wheel Spin 

 

 

 

 

Stop to fastest 

255 

Reverse Wheel Spin 

 

 

 

 

Stop to fastest 

255 

Continuous 

 

 

 

 

Positioning from 0-360 degrees 

255 

11 

13 

14 

Prism &   
Prism Rot 

Prism 

 

 

 

 

Position 1 (Open) 

Prism Rot Forward Spin 

 

 

 

 

Stop to fastest 

127 

Prism Rot Reverse Spin 

 

 

 

 

Stop to fastest 

128 

255 

12 

14 

15  Focus 

Continuous 

 

 

 

 

Focus In to Focus Out 

255 

13 

15 

16  Control 

Normal 

Reset All 

15 

Pan&Tilt Reset 

16 

23 

Color Reset 

24 

31 

Gobo Reset 

32 

39 

Shutter Reset 

40 

47 

Other Reset 

48 

55 

Display Off 

56 

63 

Display On 

64 

71 

Lamp Off 

72 

79 

Lamp On 

80 

87 

Hibernation 

88 

95 

TBD 

96 

255 

Control Board 

The Control Board offers several features: you can simply set the starting address, run the pre-programmed 
program or make a reset. 

 

The main menu is accessed by pressing Enter until the display is lit. Browse through the menu by pressing 
the arrow buttons (up, down, left, right). Press Enter in order to select the desired menu. You can change the 
selection  by  pressing  the  arrow  buttons.  Press  Enter  in  order  to  confirm.  The  functions  provided  are 
described in the following sections. 

 
Default settings shaded. 1 Basic Reload / 2 Program Reload / 3 Private Reload 

   

Conne

c

t   

DMX   Address

   

XXX   

DMX   address   setting   

Wireless

   

   

Wireless   Enabled   

Li

gh

t   

Turn   On/Off   

ON/OFF   

Lamp   On   

Automatic   

ON/OFF

   

Lamp   On/off   when   power   
on   

Содержание Ion 132B

Страница 1: ...USER MANUAL Read the user manual before turning on the product...

Страница 2: ...re device 2 User manual 3 Omega holder with quick lock fastener 4 DMX cable 3m 5 PowerCon power supply cable 1 5m 6 Safety rope SAFETY INSTRUCTIONS This device has left our factory in absolutely perfe...

Страница 3: ...me If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings concerning the power cords are also valid for possible exten...

Страница 4: ...heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunder...

Страница 5: ...5 damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock crash etc...

Страница 6: ...Features DMX channels 13 15 16 Color wheel 14 1 colors Static gobo wheel 17 1 gobos Motorized focus Full range 0 100 dimmer Various strobe 8 facets rotating Effect wheel RDM function to change DMX ad...

Страница 7: ...ctive lens 2 Arm 3 Base 4 Handle 5 Wireless indicator 6 Display 7 Microphone 8 Left button 9 Down buttom 10 Enter button 11 Up button 12 Right button 13 3 PIN DMX input socket 14 3 PIN DMX output sock...

Страница 8: ...anded Please follow the lamp manufacturer s notes Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non obs...

Страница 9: ...gging or servicing the fixture staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety r...

Страница 10: ...tc within a distance of min 0 5 m CAUTION Use an appropriate clamp to rig the fixture on the truss Follow the instructions mentioned at the bottom of the base Make sure that the device is fixed proper...

Страница 11: ...um drop distance must never exceed 20 cm A safety bond which already hold the strain of a crash or which is defective must not be used again DANGER TO LIFE Before taking into operation for the first t...

Страница 12: ...with another Occupation of the XLR connection If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first fixture in the...

Страница 13: ...ter you connected the effect to the mains the fixture starts running During the reset the motors are trimmed and the device is ready for use afterwards Stand Alone operation In the Stand Alone mode th...

Страница 14: ...ol Channe l name function Min DMX Max DMX St Ex1 Ex 2 1 1 1 Pan Pan Coarse 0 255 2 2 Pan fine Pan Fine 0 255 2 3 3 Tilt Tilt Coarse 0 255 4 4 Tilt fine Tilt Fine 0 255 3 5 5 Movment Speed fastest to S...

Страница 15: ...Position 13 204 220 Position 14 221 237 Position 15 238 255 Forward Spin Stop to fastest 0 255 Reverse Spin Stop to fastest 0 255 Continuous Positioning from 0 360 degrees 0 255 9 11 12 Gobo Function...

Страница 16: ...3 Display On 64 71 Lamp Off 72 79 Lamp On 80 87 Hibernation 88 95 TBD 96 255 Control Board The Control Board offers several features you can simply set the starting address run the pre programmed prog...

Страница 17: ...Software Ver 1U01 V1 0 00 2U01 V1 0 00 Version of each IC Set Reset All Pan Tilt Colors Gobos Shutter Others Reset all Reset Pan Tilt Reset Colors Reset Gobos Reset Shutter Reset Others Movment Pan R...

Страница 18: ...Chase Chase Part 1 Chase Part 2 Chase Part 3 Chase 1 8 Chase 1 Chase 1 8 Chase 2 Chase 1 8 Chase 3 Select and run auto program Edit Chase Chase 1 Chase 8 Chase Test Step 01 Step 64 SCxxx SCxxx Test Be...

Страница 19: ...sius degree Fahrenheit Fan speed With this function you can display the current fan speed The display shows XXXX X stands for Hz Initial status With this function you can display with which value the...

Страница 20: ...ed after a predefined period of time of no DMX activity In standby mode the lamp LEDs and all motors will power down if no DMX signal is sent to the fixture for a period of e g 15 minutes can be user...

Страница 21: ...of RDM parameters depend on the optional RDM controller being used RDM Parameter ID s Slot 21 22 Value Category _Network Management DISC_UNIQUE_BRANCH 0x0001 DISC_MUTE 0x0002 DISC_UN_MUTE 0x0003 Categ...

Страница 22: ...different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop The Slave uni...

Страница 23: ...ess the Enter button to confirm Press Up or Down to select the desired value Press the Enter button to confirm Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 and Progra...

Страница 24: ...and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts like axles eyes and others must not sh...

Страница 25: ...rther questions please contact your dealer TECHNICAL SPECIFICATIONS Power supply 100 240 V AC 50 60 Hz Power consumption 190 W DMX control channels 13 15 16 DMX512 connection 3 pin XLR Sound control v...

Отзывы: