7. Reserve: it is possible to set the value of the tank Reserve warning as a percentage of the maximum
amount of liquid the tank can hold, 0 to 50 %: with reserve = 0%, no warning of Reserve Level is
given.
Use the
↑
↓
buttons to change the value, OK to confirm,
←
to cancel.
8. Receive Configuration: to facilitate installation of the sensor on multiple identical tanks, it is
possible to perform calibration on the first tank then load the calibration on the display unit, storing it
in one of three available programs: select the program with
↑
↓
and confirm with OK; it is then
possible to start loading the calibration with OK, or
←
to cancel
.
.
9.
Send Configuration: once a calibration is loaded to a program (1-3), it is possible to send it to a
new sensor: select the program with
↑
↓
and confirm with OK; it is then possible to start
loading the calibration with OK, or
←
to cancel
.
NOTE: The program remains stored in memory even when the system is turned off.
NOTE: once the calibration has been imported, it is important to perform the offset calibration