4-44
06- Auto Run(Auto Sequencer) function
06- 00
Auto Run( sequencer) mode selection
Range
【
0
】
:Disabled
【
1
】
:Single cycle (Continues to run from the unfinished step if restarted).
【
2
】
:Periodic cycle. (Continues to run from the unfinished step if restarted).
【
3
】
:Single cycle, then holds the speed of final step to run.
(Continues to run from the unfinished step if restarted).
【
4
】
:Single cycle. (Starts a new cycle if restarted).
【
5
】
:Periodic cycle. (Starts a new cycle if restarted).
【
6
】
:Single cycle, then hold the speed of final step to run.
(Starts a new cycle if restarted).
Frequency of the step 0 is set by parameter 05-01 keypad Frequency.
06- 01
Auto _ Run Mode Frequency Command 1
06- 02
Auto _ Run Mode Frequency Command 2
06- 03
Auto _ Run Mode Frequency Command 3
06- 04
Auto _ Run Mode Frequency Command 4
06- 05
Auto _ Run Mode Frequency Command 5
06- 06
Auto _ Run Mode Frequency Command 6
06- 07
Auto _ Run Mode Frequency Command 7
Range
【
0.00 ~ 650.00
】
Hz
06- 16
Auto_ Run Mode Running Time Setting0
06- 17
Auto_ Run Mode Running Time Setting1
06- 18
Auto_ Run Mode Running Time Setting2
06- 19
Auto_ Run Mode Running Time Setting3
06- 20
Auto_ Run Mode Running Time Setting4
06- 21
Auto_ Run Mode Running Time Setting5
06- 22
Auto_ Run Mode Running Time Setting6
06- 23
Auto_ Run Mode Running Time Setting7
Range
【
0.00 ~ 3600.0
】
Sec
06- 32
Auto_ Run Mode Running Direction0
06- 33
Auto_ Run Mode Running Direction1
06- 34
Auto_ Run Mode Running Direction2
06- 35
Auto_ Run Mode Running Direction3
06- 36
Auto_ Run Mode Running Direction4