4-15
Group 06- Auto Run(Auto Sequencer) function
No. Description
Range
Factory
Setting
Unit Note
06-00
Auto Run
(sequencer)
mode selection
0: Disabled.
1: Single cycle.
(Continues to run from the Unfinished
step if restarted).
2: Periodic cycle.
(Continues to run from the unfinished
step if restarted).
3: Single cycle, then holds the speed Of
final step to run.
(Continues to run from the unfinished
step if restarted).
4: Single cycle.
(Starts a new cycle if restarted).
5: Periodic cycle.
(Starts a new cycle if restarted).
6: Single cycle, then hold the speed of
final step to run
(Starts a new cycle if restarted).
0 -
06-01
Auto _ Run Mode
frequency command 1
0.00 Hz *1
06-02
Auto _ Run Mode
frequency command 2
0.00 Hz *1
06-03
Auto _ Run Mode
frequency command 3
0.00 Hz *1
06-04
Auto _ Run Mode
frequency command 4
0.00 Hz *1
06-05
Auto _ Run Mode
frequency command 5
0.00 Hz *1
06-06
Auto _ Run Mode
frequency command 6
0.00 Hz *1
06-07
Auto _ Run Mode
frequency command 7
0.00~650.00
0.00 Hz *1
06-08
~
06-15
Reserved
06-16
Auto_ Run Mode
running time setting 0
0.0 s
06-17
Auto_ Run Mode
running time setting 1
0.0 s
06-18
Auto_ Run Mode
running time setting 2
0.0 s
06-19
Auto_ Run Mode
running time setting 3
0.0 s
06-20
Auto_ Run Mode
running time setting 4
0.0 s
06-21
Auto_ Run Mode
running time setting 5
0.0 s
06-22
Auto_ Run Mode
running time setting 6
0.0 s
06-23
Auto_ Run Mode
running time setting 7
0.0 ~ 3600.0
0.0 s
06-24
~
06-31
Reserved
06-32
Auto_ Run Mode
running direction 0
0 -
06-33
Auto_ Run Mode
running direction 1
0: Stop
1: Forward
2: Reverse
0 -