![TECO-Westinghouse L510-101-H1-U Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/teco-westinghouse/l510-101-h1-u/l510-101-h1-u_startup-manual_1072544043.webp)
4-9
Group 00: Basic Parameters
Code
Parameter Name
Setting Range
Default
Unit
Note
00-00
Control Method
0: V/F mode
0
-
*1
1: SLV mode
00-01
Motor Rotation
0: Forward
0
-
*1
1: Reverse
00-02
Main Run Source Selection
0: Keypad
0
-
1: External Run/Stop
2: Communication
00-03
Alternative Run Source Selection
0: Keypad
0
-
1: External Run/Stop
2: Communication
00-04
Operation modes for external
terminals
0: Forward/Stop-Reverse/Stop
0
-
1: Run/Stop-Reverse/Forward
2: 3-Wire Control Mode-Run/Stop
00-05
Main Frequency Source Selection
0: Keypad
0
-
1: Potentiometer on Keypad
2: External AVI Analog Signal Input
3: External ACI Analog Signal Input
4: External Up/Down Freq. Control
5: Communication Setting Freq.
6: PID Output Freq.
00-06
Alternative Frequency Source
Selection
0: Keypad
4
-
1: Potentiometer on Keypad
2: External AVI Analog Signal Input
3: External ACI Analog Signal Input
4: External Up/Down Freq. Control
5: Communication Setting Freq.
6: PID Output Freq.
00-07
Main and Alternative Frequency
Command modes
0: Main or Alternative Freq.
0
-
1: Main + Alternative Freq.
00-08
Communication Frequency
Command
0.00~599.00
Hz
*4
00-09
Frequency command Save mode
(Communication mode)
0: Save Freq. before powering down
0
-
1: Save communication Freq.
00-10
Initial Frequency Selection ( keypad
mode)
0: Set by Current Freq. Command
0
-
1: Set by 0 Freq. Command
2: Set by 00-11
00-11
Initial Frequency Keypad mode
0.00~599.00
50.00/60.00
Hz
00-12
Frequency Upper Limit
0.01~599.00
50.00/60.00
Hz
00-13
Frequency Lower Limit
0.00~598.99
0.00
Hz
00-14
Acceleration Time 1
0.1~3600.0
10.0
s
*1
00-15
Deceleration Time 1
0.1~3600.0
10.0
s
*1
00-16
Acceleration Time 2
0.1~3600.0
10.0
s
*1
00-17
Deceleration Time 2
0.1~3600.0
10.0
s
*1
00-18
Jog Frequency
1.00~25.00
2.00
Hz
*1