4-16
Group 08: Protection Parameters
Code
Parameter Name
Setting Range
Default
Unit
Notes
x1xxx: Disable over voltage Prevention
in Run Mode
08-01
Trip Prevention Level
During Acceleration (%)
50 ~ 200
by series
%
08-02
Trip Prevention Level
During Deceleration (%)
50 ~ 200
by series
08-03
Trip Prevention Level In
Run Mode (%)
50 ~ 200
by series
08-04
over voltage Prevention
Level in Run Mode
350~390
380
VDC
*1
08-05
Electronic Motor
Overload Protection
Operation Mode
xxxx0: Disable Electronic Motor Overload
Protection
00001
-
xxxx1: Enable Electronic Motor Overload
Protection
xxx0x: Motor Overload Cold Start
xxx1x: Motor Overload Hot Start
xx0xx: Standard Motor
xx1xx: Invertor Duty Motor ( Force Vent)
08-06
Operation After
Overload Protection is
Activated
0: Coast-to-Stop After Overload
Protection is Activated
1: Drive Will Not Trip when Overload
Protection is Activated (OL1)
0
-
08-07
Over heat Protection
(cooling fan control)
0: Auto (Depends on temp.)
1: Operate while in RUN mode
2: Always Run
3: Disabled
1
-
08-08
AVR Function
(Auto Voltage
Regulation)
0: AVR function enable
4
-
1: AVR function Disable
2: AVR function disable for stop
3: AVR function disable for deceleration
4: AVR function disable for stop and
deceleration.
5: When VDC>(360V/740V), AVR function
disable for stop and deceleration.
08-09
Input phase lost
protection
0: Disabled
1: Enabled
0
-
08-10
PTC Overheat Function
0: Disable
0
1: Decelerate to stop
2: Coast to stop
3: Continue running, when
warning level
is
reached. Coast to stop, when
protection level
is reached.
08-11
PTC Signal Smoothing Time
0.01~10.00
0.2
Sec