Reset of the partial hour counter
Switch the device off by using the main switch on the side of the electric box.
Press both switches and hold them, switch the device on by putting the main
switch in ON position; once finished the LED lights sequence, release the switches and
the hour counter C2 will be brought to 0000.
Clock set-up
Switch the device off by using the stand-by switch (the main switch has to remain in ON
position).
The display will visualize the current time, to adjust it press the switch and then operate with the
-/+ switches to increase or decrease the time displayed.
Note: the timer is equipped with a battery for time memorization, if the device remains without power
supply for a period of more than 30 days, the timer will be reset and it will have to be set again.
Indication of boiler cleaning operation (C A L C )
The controller has been programmed to warn the user about the ordinary maintenance period; the
system has been programmed in order to warn each 20 effective working hours (steam solenoid valve
on). Proceed as described in the section 9.1
“boiler maintenance” in order to perform the liquids
drainage.
Warning indication (C A L C ) restoration
After having performed the maintenance, press and hold the switch and switch the device off by
using the switch . The warning C A L C will be restored.
Detergent refilling
Once the detergent is finished, the light will switch on and the appliance will emit a continuous
acoustic signal, the detergent pump will be automatically disconnected; therefore proceed by pouring
detergent into the tank (6).
Note: the acoustic signal for the lack of detergent (continuous tone) prevails on the acoustic signal for
the lack of water (intermittent tone).
Integrated vacuum cleaner (optional)
In case of complete obstruction of the vacuum inlet, a safety system will automatically block the
appliance after one minute. To reactivate the integrated vacuum cleaner switch the appliance off by
turning the general power switch (4), wait 10 seconds before switching it on again.