8. OPERATING INSTRUCTIONS
(a) Fix the vacuum drum (18) on the round black base (17) by operating on the hooks (19).
(b) Insert the plug of the vacuum cleaner (23) into the outlet located on the right side of the steam
generator (14) (only for models with external vacuum cleaner).
(c) Insert one end of the hose (25) into the vacuum head (22) and the other end into the vacuum hose
outlet (15), activating the locking latch (16) (only for models with integrated vacuum cleaner).
(d) Remove the tanks caps (6 and 7) and fill in water and detergent in the relevant tanks,
water inside
the blue funnel and detergent into the yellow funnel. It is recommended to be very careful
during this process because an inverted filling up
(detergent into the water tank or water into
detergent tank)
causes a steam generator fault.
(e) When using detergent (not foamy for extractions machines), please follow the specific instructions:
normally 1 liter of detergent for every 10 liters of water (detergent percentage about 10%), making
sure to fill in first the detergent to obtain a better mixing.
Please be careful with the detergent to be
used as some available in commerce will emanate highly toxic gases when heated above
100°C. Always consult the MSDS datasheet from the supplier.
The detergent tank has to be filled only with detergent diluted with water,
not with water only
,
unless you are not using demineralized water.
The usage of water only (not demineralized) instead of detergent causes faults to the mixing circuit.
(f) Insert the plug (1) into the electrical outlet, making sure that the voltage and the amperage correspond
with the data printed on the plate located on the rear side of the unit.
(g) Switch the unit on by rotating the main switch onto position ON or onto the desired
power (only for models with power regulation).
Activate the standby and the boiler
switches.
(h) The machine is equipped with a protective system against thermal shock. Therefore, in case of water
lacking inside the boiler, the system automatically disconnects the heating elements supply. This
situation is recognizable thanks t
o the blinking LED light on the “boiler switch” . The system
can intervene also after the boiler refilling once performed the mud drain during the maintenance
process.