The latch version (Motor LatchBolt lock) is specially designed to ensure self-locking when the
door closes.
When locked, there must be a 0.5 mm gap between lock bolt and
locking surface.
Insert the keypad cable into the lock connector "1", making sure it
is fully inserted and locked.
Any alarm interface or battery holder Needs to be connected to the
lock connector “2”. To remove the cable, bring the connector
upwards and carefully pull it out.
The Push & Pull version (T5101/MP) is supplied by default with RCS option, where closing is
triggered by an external signal (i.e. boltwork switch). This avoids the motor to be activated when
boltworks are not expanded yet.
It’s recommended to correctly use this signal to avoid motor damages.
Lock is also programmed by default with 8 seconds automatic
reclosure, which can be modified upon request. This means that if
the lock will open but the external signal don’t (i.e. boltworks not
expanded), lock will auromatically close after 8 seconds (smart
reclosure).
The maximum load applicable to the bolt must not exceed the limit values specified in the
table below. Contact Tecnosicurezza in case of heavier loads.
Lock reference
Lock version
Maximum force to apply
on the bolt
Maximum load pulled up
and pushed by the bolt
T5101/M
Pull and spring version – Cass B
1KN (100 Kg)
4N (400 gr)
T5101/MP
Push and pull version – Class B
1KN (100 Kg)
30 N (3 Kg)
T5101/M/S
Latch version
1KN (100 Kg)
-
The distance between the lock and the locking edge must be between
a minimum of 6 mm and a maximum of 10 mm.