II_DigiTech_05_eng
13 of 20
Installation instructions
DigiTech
It’s possible to connect a relocker to the lock cover through the appropriate holes.
MotorLock and Motor LatchBolt locks installation instructions
MotorLock and Motor LatchBolt locks are locks with, respectively, a motor driven dead bolt and
a motor driven spring bolt, whose block is carried out by a motor.
By entering a valid code, the motor retracts the bolt which remains in the open position for about
8 seconds and then automatically returns to the locked position.
If the manual relocking option is selected, the bolt closes by pressing and holding the button
.
Both lock versions can be mounted in all four mounting directions (RH, LH, VU, VD).
Locks are supplied with metric (M6) mounting screws. Upon request, Imperial 1/4-20 UNC
format mounting screws are available.
Secure the cable inside the special groove located on the lock
cover, ensuring that it is not stretched when turning the spindle.
Fix the lock using the appropriate mounting screws.
Connect the keypad cable to the lock connector "ENT", making sure it is fully inserted and
locked. Any alarm interface or battery holder needs to be connected to the lock connector
“BAT”. To remove the cable, bring the connector upwards and carefully pull it out.
Fix the relocker plate with M4 self tapping flat head screws.
Length must be 6 mm + plate thickness.
(i.e. 6 mm + 2 mm plate = 8 mm screw)
In the locked position, there should be approximately 1 mm clearance
between the lock bolt and the cavity in the blocking bar of the boltwork.
The bolt must be able to move freely without applying any force on it.
In open position, there should be aminimum of 3 mm and maximum
of 5 mm clearance between the lock bolt and the blocking bar of the
boltwork.