II_DigiTech_05_eng
5 of 20
Installation instructions
DigiTech
In order to prevent the screws from loosening, it is recommended the use of LOCTITE®
threadlocker and/or specific washers positioned under the head of the fixing screw.
The diameter of the passage hole for the connection cable or the spindle must not
exceed 11 mm.
The hole must be completely cleaned of drill dust and sharp edges.
Do not lubricate locks.
In the locked position, the distance between the bolt and the boltwork part which moves
the lock bolt must comply with the following specifications for each type of lock.
Any component to be fixed to the lock bolt must be previously approved by
Tecnosicurezza before installation. In any case, the maximum load must not exceed 4 N
for T5101/M and 30 N for the reinforced model T5101/MP.
Secure the cables away from moving parts by using cable ties and cable ties bases.
If placed in normal domestic or office environments, the locks do not require particular
maintenance; in any case, after 10,000 opening/closing cycles, it is recommended to run
a test that verifies the correct and complete operation of the product.
Use only DURACELL™ 9 Volt Alkaline batteries, or battery holders with DURACELL™ 1,5
Volt Alkaline batteries. Alternatively it is also possible to use a stabilized power supply
from 12 V to 24 V and 1 A, with relative power supply interface (p.n. T6006).
A series of acoustic signals during opening indicate a low battery level. In this case, the
battery must be replaced.
Do not use cleaning agents with chemical, abrasive or alcohol-containing additives to
clean the components. Use only a damp cloth.
Do not spray liquid directly onto the components.