PAGE 4
User Manual
- Ecomatic 2010
3.
System Use
POWER SUPPLY
The power supply can be 12Vdc direct current
or 24Vdc direct current (depending upon the
application and the relay kit ordered with the
system).
Always supply power to the system with the
correct voltage in order to avoid breakdowns
and system failures.
After system installation, connect it to the
battery. Connect the blue wire to the positive
terminal and the brown wire to the negative
terminal.
Even though the system is protected against
reverse polarity of the power supply, always
be careful to perform the correct cable
connection.
To activate the system, release the emergency
push-button.
Press the emergency push-button whenever
needed.
Before disconnecting the control unit, press
the main push-button or the emergency
push-button to make sure the
system isn’t powered.
SYSTEM START
The system is started by the switch button
#1 which will activate the system by the
main relay contained in the shunt box. If the
emergency push-button is not released, the
system will not start.
If the system has been successfully started,
the display will turn on.
ENGINE START/STOP
With the engine turned off and the oil
pressure warning light turned on, (warning
light #3), the engine can be started by
holding the Engine Start (pushbutton #5) for
at least three seconds.
The three seconds are those needed by the
diesel engine glow plugs.
If the engine is running, pushing again the
pushbutton #5 will activate the engine stop.
If the engine is running, the light #3 indicates
the amount of fuel reserve.