2
04/06/2019 Rev:1.0.0
7.2 Programmed routine maintenance (only for TECNO PRIME)
Maintenance should be carried out according to the effective running time of the system so to ensure ef-
fi cient performance and avoid serious mechanical damages.
The TECNO PRIME vacuum cleaners are controlled by a computer which also checks the routine main-
tenance cycles:
• Emptying the dust collection bin (for confi guration 1)
• Replacing the dust collection bag (for confi guration 2)
• Cleaning the fi lter
In confi guration 1, on the dust-level gauge of the dust collection bin the user can choose to keep the
maintenance parameters set by the manufacturer in the computer or change them to better suit to specifi c
needs.
It is also possible to save telephone numbers to be dialled in case technical assistance is needed.
Furthermore, when the alarm signals the need for routine maintenance (dirty fi lter, full dust bag, and full
dust bin) the operator can decide whether to switch off the system immediately and satisfy maintenance
requirements or fi nish his job.
The unit can gauge:
- the dust level in the dust bag (when used, i.e. in BI-VAC confi guration)
- the level of fi lter effi ciency (i.e. dirty fi lter alarm)
- the vacuum level in the system
- the need to carry out extraordinary maintenance
English
13
7 - MAINTENANCE
7.1 Programmed routine maintenance
Maintenance should be carried out according to the effective running time of the system so to ensure
effi cient performance and avoid serious mechanical damages.
BEFORE CARRYING OUT ANY MAINTENANCE
OPERATION, IT IS MANDATORY TO UNPLUG THE POWER
SUPPLY CABLE FROM THE POWER SUPPLY INLET.
PROTECTIVE MASK AND GLOVES MUST
ABSOLUTELY BE WORN
Working time
(h)
Maintenance
Executor
4
Filter cleaning
User
6
Dust bin emptying
User
32
Filter replacement
Technical assistance
54
Air exhaust blockage
Technical assistance
350
Motor carbons replacement
Technical assistance