3
Installation
INSTALLATION
All electrical wiring must be in
compliance with the appropriate IEE
regulations and carried out by a qualified
electrician.
The cooker must be supplied via a
suitable double pole isolating switch
placed in a readily accessible position
adjacent to the oven.
Each cooker is equipped with a data
plate (see fig. 1) indicating the rated
input and voltage at which the oven
should operate.
Before installing the cooker the electricity
must be turned off.
The electrical connections must be
connected to the terminal block as
detailed opposite. A cable of the correct
rating of this appliance must be used
type H05 RR-F section 4 mm
2
.
Cable must be able to withstand a
temperature rise of 75°C above ambient
temperature.
TECHNICAL DATA
230 Volts AC - 50 Hz
Static top oven
– Top element
0.7 kW
– Bottom element
1.1 kW
– Grill element
2.1 kW
Fan Bottom Oven
– Fan element
2.5 kW
Maximum power rating
– Top oven
2.1 kW
– Bottom oven
2.5 kW
Hotplate
– Front left
2.0 kW
– Back left
1.0 kW
– Back right
1.5 kW
– Front right
1.0 kW
Oven lamp
15 W
300 °C, miniature edison screw
Maximum rated power
10,155 W