ELECTRODES
When operating, the electrodes must be kept clean and their
diameter must be kept suitable for the work to be carried out.
Excessively worn electrodes must be replaced.
With water cooled arms, do not use sealing products to
remove water leakage on the electrode taper. To facilitate
electrode removal and to prevent from both taper seizure and
leakage, use high conductivity grease similar to the standard
one.
COOLING CIRCUIT (ON ITEM 7903 ONLY)
Check that cooling water circulates freely and in the required
quantity and that the input temperature is within 10 and 30°C.
Check the status of both water hoses and corresponding
connections.
If the welder is to be stored during the winter in a cold
environment, first carefully drain the cooling circuit to prevent
damage caused by frozen water.
ELECTRICAL CIRCUIT
Periodically check ground efficiency.
Periodically check the mains cable.
EXTRAORDINARY MAINTENANCE
If the welder overheats, check that the duty cycle is not too high
(table 4), the electrode tip diameter is correct (table 2); on water
cooled models check that water flow is adequate.
Item 7903 is equipped with a thermostatic protection which
stops the welder in case of insufficient water. The thermostat
does not protect the transformer against work overloading.
If performances are lower than expected check:
that, when welding, line voltage drop is lower than 15%;
that the supply cables section is adequate;
that the electrodes diameter is appropriate for the work to be
carried out;
on item 7903 that the cooling water flows in the required
quantity;
that the set welding force is adequate for the work in process.
SPARE PARTS
Look at the exploded views and at the spare parts list at the end
of this instruction manual to identify the code of the required
parts. The first number of the code has the following meaning:
1....
standard components widely available from industrial
suppliers (e.g. screws, washers, nuts, etc.).
2....
commercial components which, providing that the
same quality parameters are adopted, can be purchased
anywhere (hoses, switches etc.).
3....
components manufactured by TECNA
4....
components manufactured by TECNA
5....
electronic circuits and assemblies manufactured by
TECNA.
7....
assemblies composed of parts belonging to any or all
of the above codes but which for the sake of simplicity are
available ready-assembled.
All spare parts, including standard or commercial ones, are
available from TECNA. When ordering please always state code
number, and quantity of the spare parts, voltage and frequency,
the serial number, and year of manufacture of the welder. The
code number followed by an asterisk warns that the part
changes depending on the mains voltage.
REMEDIES FOR WELDS IMPERFECTIONS.
This chapter has been introduced in order to facilitate the troubleshooting of the most common imperfections caused by incorrect
adjustment. Notice that each one can be caused by different causes as there are many parameters affecting the welding process . The
following table specifically refers to low carbon steel spot welding, but, with the due consideration, it can also be useful for other
applications.
FAULT
POSSIBLE CAUSE
POSSIBLE REMEDY
Low welding current.
Increase it.
Low welding time.
Increase it.
Weak welding
Too high electrodes force.
Reduce pressure.
Lacking electrodes maintenance or too high
electrodes diameter.
Clean and line up the electrodes, restore their
dimensions.
Faulty pieces contact.
Increase the electrodes force.
Paint or dirt among pieces.
Clean the pieces.
Inadequate electrodes cooling.
Check the cooling circuit.
Faulty pieces contact or pieces and electrodes
faulty contact.
Increase the electrodes force by increasing
pressure.
Spatter of molten
Too high welding current.
Reduce it.
material
Too high welding time.
Reduce it.
Too small electrodes diameter.
Adjust diameter to the value shown on the table.
Inadequate welding force.
Increase pressure.
Electrodes faulty clamping of the pieces.
Check stroke.
Too high welding current.
Reduce it.
Inadequate welding force.
Increase welding pressure.
Burned welds or welds
Oxidised pieces to weld.
Clean them by means of emery paper.
showing either craters or
fissures.
Faulty pieces contact or pieces and electrodes
faulty contact.
Increase electrodes force.
Faulty pieces lining up.
Correct it.
Electrodes tips deformations.
Restore them to the correct size.
Work pieces stuck
Too high welding current.
Reduce it.
on the electrode
Inadequate electrodes diameter.
Restore it to the correct dimensions.
Inadequate welding force.
Increase the welding pressure.
Electrodes and connections
reduced life (position 21).
Under-sized electrode in comparison with the
work to be done
Check both size and contact diameter.
Secondary
connection
reduced life and oxidation.
Heating caused by an inadequate clamping of
the flexible connection.
Carefully tighten the clamping screws.
Too high heating caused by a too high welding
rate.
Reduce it.
"