11
breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is
accessible after the unit installation.
Do not use extension cords or an adapter plugs with this unit.
However, if it is necessary
to use an extension cord, use an approved dehumidifier extension cord only (available at
most local hardware stores).
To avoid the possibility of personal injury, always disconnect the power supply to the unit,
before installing and/or servicing.
3. Components
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed or
not replaced in the proper position.
Auto Shut Off
The water level control switch shuts off the
dehumidifier when the bucket is full, or
when the bucket is removed or not replaced
in the proper position. When the setting
humidity is reached, the unit will be shut off
automatically.
Auto Defrost
When frost builds up on the evaporator
coils, the compressor will cycle off and the
fan will continue to run until the frost
disappears.
Auto-Restart(on some models)
If the unit breaks off unexpectedly due to the
power cut, it will restart with the previous function setting automatically when the power
resumes.
Wait 3 minutes before resuming operation. After the unit has stopped, it cannot be restarted
operation in the first 3 minutes. This is to protect the unit. Operation will automatically start
after 3 minutes
Display
Shows the set % humidity level while setting, then shows the actual ( ± 5% accuracy) room %
humidity level.
Error Codes
:
E1 Humidity sensor error--Unplug the unit and plug it back in. If error repeats, call for
service.
E2 Temperature sensor error-- Unplug the unit and plug it back in. If error repeats, call for
service.
Protection Codes:
P1 Unit is defrosting-- Allow the unit time to automatically defrost. The error will clear after
the unit self-defrosts.
P2 Bucket is full or bucket is not in the right position-- Empty the bucket and replace in the
right position.
NOTE: When more than one errors occur, the priority of the code display order is: P2--E2--E1--
P1.