background image

 

 

Water

 

temperature

 

over

 

125ºF

  

can

 

cause

 

severe

 

burns

 

instantly

 

or

 

death

 

from

 

scalds.

 

 

Children,

 

disabled

 

and

 

elderly

 

are

 

at

 

highest

 

risk

 

of

 

being

 

scalded.

 

 

See

 

instruc

on

 

manual

 

before

 

se

ng

 

temperature

 

at

 

water

 

heater.

 

 

Feel

 

water

 

before

  

bathing

 

or

 

showering.

 

 

Temperature

 

limi

ng

 

valves

 

are

  

available,

 

see

 

manual.

 

All

 

wiring

 

must

 

be

 

done

 

in

 

accordance

 

with

 

Na

onal,

 

State

 

and

 

local

 

codes.

 

Adhere

 

to

 

the

 

Na

onal

 

Electric

 

Code

 ‐ 

ANSI/NFPA

 

70

1990

 

in

 

the

 

absence

 

of

 

any

 

other

 

codes.

 

 

Power

 

must

 

be

 

shut

 

o

ff 

before

 

installing

 

or

 

servic

ing

  

the

 

heater.

  

A

 

separate

 

shut

 

o

ff 

switch

 

should

 

be

 

installed

 

to

 

support

 

future

 

servicing

 

or

 

an

 

emergency

 

shutdown.

 

The

 

en

re

 

hea

ng

 

system

 

should

 

have

 

its

 

own

 

designated

 

electrical

 

circuit.

 

 

The

 

Techtanium

 

heater

 

operates

 

in

 

much

 

the

 

same

 

way

 

as

 

an

 

addi

onal

 

hea

ng

 

zone,

 

either

 

u

lizing

 

the

 

same

 

circulator

 

as

 

household

 

hea

ng

 

or

 

its

 

own

 

circulator.

  

The

 

heater

 

temperature

 

is

 

maintained

 

by

 

the

 

use

 

of

 

an

 

immersion

 

type

 

aq

uastat.

   

The

 

aquastat

  

is

 

installed

  

into

  

the

 

im

mersion

  

well

 

on

 

the

 

heater.

  

 

The

 

aquastat

 

operates

 

in

 

much

 

the

 

same

 

way

 

as

 

a

 

thermostat.

 

When

 

the

 

temperature

 

falls

 

inside

 

the

  

tank

  

the

  

set

  

of

  

contacts

  

make

 

(close)

  

and

 

when

 

the

 

temperature

 

rises

 

the

 

contacts

  

break

 

(open).

 

 

The

 

aquastat

   

should

 

be

 �

ed

 

into

 

the

 

boiler

 

sys

tem

 

and

 

controls.

 

When

 

the

 

tank

 

calls

 

for

 

heat

 

the

 

aquastat

 

contacts

 

close

 

and

 

signal

 

the

 

boiler

 

con

trols,

 

allowing

 

the

 

boiler

 

to

 

maintain

 

temperature

 

and

 

proper

 

opera

on

 

of

 

the

 

tank

 

circulator.

 

 

DHT

 

recommends

 

the

 

use

 

of

 

a

 

priority

 

control

  

to

 

help

 

the

 

boiler

 

maintain

 

desired

 

temperature

 

and

 

sa

sfy

 

the

 

tank's

 

BTU

 

requirements.

 

 

The

 

Techtanium

 

heater

 

recovery

 

ra

ngs

 

are

 

based

 

on

 

the

 

boiler's

 

ability

 

to

 

maintain

 

180

 

degrees

 

Fahrenheit.

  

It

 

is

 

important

 

that

 

the

 

installer,

 

plumber

 

or

 

hea

ng

 

technician

 

responsible

  

for

   

installing

   

the

   

heater,

   

make

 

certain

 

that

 

the

 

boiler

 

capacity

 

(BTU)

 

is

 

adequate

 

to

 

sa

sfy

 

the

 

heater's

 

BTU

 

requirements.

 

11

 

V Wiring 

Содержание MP 20

Страница 1: ...intenance can cause injury or property damage Refer to this manual For assistance or addi onal informa on consult a quali ed Installer or Service Agency Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of this or any other appliance Installa on and service must be performed by a quali ed Installer or Service Agency WARNING FOR YOUR SAFETY INDIRECT WATER HEATERS Ins...

Страница 2: ...table piping shall connect the drain pan to a properly operating floor drain Relief Valve Requirements Caution To reduce the risk of excessive pressures and temperatures in this water heater install temperature and pressure protective equipment required by local codes It should be no less than a combination tempera ture and pressure relief valve certified by a nationally recognized testing laborat...

Страница 3: ...wers require large quantities of hot water in a short period of time Contact fixture manufacturer for quantity of water required Generally speaking these circumstances can only be met with larger storage volumes c Domestic Water Temperature Most residential usage will be satisfied with 119ºF water the temperature setting recommended by the Consumer Product Safety Commission Some applications s uc ...

Страница 4: ...4 22 4 22 4 B 31 1 39 47 9 56 C 27 6 36 44 4 53 2 Boiler Supply Boiler Return Drain Thermometer Cold Water Inlet Hot Water Outlet T P Relief Valve Drain Valve Boiler Supply Boiler Return Front of Tank Tank Thermostat located under cover Dimensions A B C 4 ...

Страница 5: ...t 5 GPM 8 GPM 12 GPM MP 20 1 2 2 9 6 2 hd MP 32 1 6 3 8 8 0 hd MP 40 1 6 3 6 7 6 hd MP 50 1 8 4 2 8 8 hd Pressure Drop Graph 2 0 4 0 6 0 8 0 10 0 5 GPM 8 GPM 12 GPM Primary Flow Rate Head Loss FT HD PressureDrop Graph MP 20 MP 32 MP 40 MP 50 5 50 32 40 20 ...

Страница 6: ...134 95 156 111 140 000 134 95 156 111 165 000 168 119 195 000 Performance Data MP 32 Con nuous Draw Ra ngs Based Upon Boiler s Ability to Maintain 180º F Model MP 32 Circulator Flow GPM 5 5 8 8 12 12 DHW Temperature 120ºF 140ºF 120ºF 140ºF 120ºF 140ºF Boiler Hea ng Capacity in Btu Hr Output 45 000 106 78 106 78 60 000 134 97 134 97 75 000 162 116 162 116 95 000 168 120 188 134 198 141 115 000 168 ...

Страница 7: ...24 192 138 223 159 140 000 192 138 223 159 165 000 240 171 195 000 Performance Data MP 50 Con nuous Draw Ra ngs Based Upon Boiler s Ability to Maintain 180º F Model MP 50 Circulator Flow GPM 5 5 8 8 12 12 DHW Temperature 120ºF 140ºF 120ºF 140ºF 120ºF 140ºF Boiler Hea ng Capacity in Btu Hr Output 45 000 117 91 117 91 60 000 142 108 142 108 75 000 167 125 167 125 95 000 201 148 201 148 201 161 115 0...

Страница 8: ... water leakage The floor or area where the tank is installed must be capable of suppor ng the tank when filled with water Refer to the Specifica ons Table on the page 3 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Controls on this appliance could ignite vapors causing an explosion IV Installation Piping General a A...

Страница 9: ...changer Pressure Drop hd Domes c Water Connec on Sizes MP 20 5 GPM 1 2 3 4 MP 32 8 GPM 3 8 3 4 MP 40 12 GPM 7 6 3 4 MP 50 12 GPM 8 8 3 4 Tubing Type Flow Rate 10 GPM Flow Rate 15 GPM Type K 3 1 psi 6 5 PSI Type L 2 7 psi 5 7 psi Type M 2 3 psi 4 7 psi Fi ng Wrought Cast 90º Elbow 1 4 45º Elbow 1 2 Tee Run 1 2 1 2 Tee Branch 3 5 Long radius 90º Elbow 2 180º Bend 2 Gate Valve 1 ...

Страница 10: ...n the tank and the back ow device see piping diagram Refer to Thermal Expansion Tank manufacturer s lit erature for sizing and installa on informa on E Vacuum Breaker DHT recommends that a vacuum breaker be installed on the domes c piping to the heater The vacuum breaker protects the heater in the event that the tank pressure falls below atmos pheric pressure F Temperature Pressure Relief Valve T ...

Страница 11: ... or its own circulator The heater temperature is maintained by the use of an immersion type aq uastat The aquastat is installed into the im mersion well on the heater The aquastat operates in much the same way as a thermostat When the temperature falls inside the tank the set of contacts make close and when the temperature rises the contacts break open The aquastat should be ed into the boiler sys...

Страница 12: ...ntrols The con tacts open break on temperature rise when the tank reaches the set temperature Connect system wires to wiring block located under cover Auxiliary contacts Terminals C 1 purple brown for solar hea ng or other applica ons are normally closed and open break on temperature decrease This opera on is opposite most water heaters and should only be used for auxiliary equipment Set the tempe...

Страница 13: ... all other zones will stop opera on un l zone 6 is sa s ed When Zone 6 is not switched to priority all zones will operate independently Jumper Placement REMOVE the jumper between terminals ZC and ZR Connect termi nal ZC to ZC terminal on the aquastat control Connect terminal ZR to ZR terminal on the aquastat control Con rm polarity is con sistent between the boiler aquastat and the switching relay...

Страница 14: ...ed to the priority se ng and is ac vat ed all other zones will stop opera on un l zone 6 is sa s ed When Zone 6 is not switched to priority all zones will operate independently Jumper Placement The jumper should be placed between terminals ZC and ZR Con nect the isolated end switch to the aquastat on the boiler Power input Connect 120 volt as power input to terminals N and H Neutral wire to termin...

Страница 15: ...Wiring Diagrams 15 ...

Страница 16: ...Wiring Diagrams 16 ...

Страница 17: ...t water taps 4 A ach a hose to the drain valve located at the bo om of the heater and allow the heater to drain 5 Unscrew the anodes EXAMINE THE ANODES AND REPLACE IF THEY SHOW SIGNS OF DETERIORATION 6 Replacement of the Anodes The use or P T F E tape is recommended to ensure water ght connec on of the anodes Failure to inspect the anodes may result in premature failure of the heater and could voi...

Страница 18: ...ium indirect fired water heater services only one family unit in a multiple family dwelling provided that the term residential setting shall not include any usage of the Techtanium indirect fired water heater above 150 degrees Fahrenheit During the specified warranty period of the indirect fired water heater Diversified Heat Transfer Inc will repair or replace at its option without charge any indi...

Страница 19: ...da 12 Service calls not involving any malfunction or defects and maintenance in the ordinary course 13 Components of an indirect fired water heater which are not manufactured expressly for Diversified Heat Transfer such components are subject only to those warranties if any given by their manufacturers Diversified Heat Transfer does not adopt and has no responsibility for those warranties 14 Any T...

Страница 20: ... to the model and dimensions in the diagrams below When fastening the brackets to the wall make sure to use appropriate fasteners capable of suppor ng the full tank weight as speci ed below Please note that the tank may only be installed in the upright ver cal posi on Follow the piping and wiring instruc ons found in the installa on manual Optional Wall Mount Installation Instructions Models MP 20...

Отзывы: