REPLACEMENT TANK - WARRANTY  RESIDENTIAL OR COMMERCIAL APPLICATION

 

For either a residential or commercial application, the following  applies to both when a replacement tank is provided for a tank found to be under warranty.

 

The replacement  tank warranty  assumes the remaining warranty period left from the original tank purchased.

 

WHAT  IS NOT COVERED BY EITHER OF THESE WARRANTIES

 

These warranties  are void  and shall not apply under the following circumstances:

 

1. The Techtanium™ water heater was not installed or repaired by a heating contractor whose principal occupation is the sale, installation and repair of

plumbing, heating and/or air conditioning  equipment.

 

2. These warranties  cannot  be considered  as a guarantee of workmanship of an installer connected with the installation of the Techtanium water heater, or

as imposing  on Diversified  Heat Transfer liability  of any nature for unsatisfactory performance as result of faulty workmanship in the installation or repair 

which liability  is expressly disclaimed.

 

3.  The failure or malfunction  results from improper  or negligent  operation, abuse, misuse or maintenance or unauthorized  alteration.
4. Malfunctions  resulting  from, or repairs necessitated by, uses of the indirect-fired  water heater for purposes other than  that for which  it was designed, or

resulting from flood, fire, wind, lightning, freezing or any other natural disaster or act of God, an act of destruction, theft or accident.

 

5.  The original  serial number  on the indirect-fired  water heater or component  thereof cannot be readily determined.
6.  Any indirect-fired  water heater is installed in a setting containing  any type of water softener system that is not installed and maintained  in accordance

with the manufacturer’s specifications.

 

7.  The Techtanium indirect-fired  water heater is used for non-potable  applications such as pool  or process heating.
8.  The failure or malfunction  results from failure to keep the tank full of potable water, free to circulate at all times and with the tank free of damaging water

sediment  or scale deposits.

 

9.  Components of an indirect-fired  water heater which are not defective, but  must  be replaced  during  the warranty  period  as a result of reasonable  wear

and tear.

 

10. Techtanium indirect-fired  water heaters which are repaired or altered without  prior written  approval  of Diversified  Heat Transfer so as to affect adversely

their reliability.

 

11. Diversified  Heat Transfer Techtanium™ indirect-fired  water heaters installed outside of the United States and Canada.
12. Service calls not involving  any malfunction  or defects and maintenance in the ordinary course.
13. Components of an indirect-fired  water heater which are not manufactured  expressly for Diversified  Heat Transfer; such components  are subject only to

those warranties, if any, given by their manufacturers. Diversified  Heat Transfer does not  adopt  and has no responsibility  for those warranties.

 

14. Any Techtanium tank that does not have installed a new temperature and pressure relief valve bearing the American Society of Mechanical Engineers

(A.S.M.E.) listing at the time of installation.

 

FURTHER LIMITATIONS  OF WARRANTIES AND REMEDIES

 

These warranties  give you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow the exclusion or 

limitation  of incidental or consequential damages, so this limitation  or exclusion may not apply to you.

 

These are the only written  warranties applicable to Diversified Heat Transfer Techtanium™ indirect-fired  water heaters manufactured for and sold by 

Diversified  Heat Transfer. Diversified  Heat Transfer neither  assumes nor  authorizes  anyone  to assume for it any other obligation or liability in connection with 

said Techtanium indirect-fired  water heaters.

 

This warranty  does not cover expenses or labor for disassembly, removal, shipment reassembly or reinstallation;  the original  purchaser will be 

responsible  for such costs.

 

Diversified  Heat Transfer’s performance under these warranties may be contingent  on shipment  of components or equipment  from suppliers. Diversified 

Heat Transfer shall not be liable for any failure or delay in delivery due to any cause beyond its control including without  limitation, strike, labor stoppage, a 

natural  disaster (such as earthquake, flood, fire or storm), political  insurrection or the unavailability  of components, equipment or supplies.

 

MAKING A WARRANTY CLAIM

 

TO FILE A CLAIM  UNDER THESE WARRANTIES CONTACT  DIVERSIFIED HEAT TRANSFER INC. AT THIS ADDRESS:

 

439 MAIN ROAD, TOWACO,  NEW JERSEY 07082  OR CALL DIVERSIFIED HEAT TRANSFER AT (800) 221-1522 AND ASK FOR CUSTOMER SERVICE.  

At the time a claim is filed, the  original  purchaser  must  present  a copy  of the  original  sales receipt, installation bill, proof of delivery or equivalent 

documents  evidencing  both  ownership  of the Techtanium™ indirect-fired water heater and installation in the dwelling or commercial property owned by the

 

original purchaser

 

This warranty  is to be governed by and construed in accordance with  the laws of the State of New York without  regard to the principles of conflict of laws.

 

DIVERSIFIED   HEAT  TRANSFER  RESERVES THE RIGHT TO CHANGE SPECIFICATIONS OR DISCONTINUE MODELS  WITHOUT  NOTICE.

 

VII  Warranty 

19 

Содержание MP 20

Страница 1: ...intenance can cause injury or property damage Refer to this manual For assistance or addi onal informa on consult a quali ed Installer or Service Agency Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of this or any other appliance Installa on and service must be performed by a quali ed Installer or Service Agency WARNING FOR YOUR SAFETY INDIRECT WATER HEATERS Ins...

Страница 2: ...table piping shall connect the drain pan to a properly operating floor drain Relief Valve Requirements Caution To reduce the risk of excessive pressures and temperatures in this water heater install temperature and pressure protective equipment required by local codes It should be no less than a combination tempera ture and pressure relief valve certified by a nationally recognized testing laborat...

Страница 3: ...wers require large quantities of hot water in a short period of time Contact fixture manufacturer for quantity of water required Generally speaking these circumstances can only be met with larger storage volumes c Domestic Water Temperature Most residential usage will be satisfied with 119ºF water the temperature setting recommended by the Consumer Product Safety Commission Some applications s uc ...

Страница 4: ...4 22 4 22 4 B 31 1 39 47 9 56 C 27 6 36 44 4 53 2 Boiler Supply Boiler Return Drain Thermometer Cold Water Inlet Hot Water Outlet T P Relief Valve Drain Valve Boiler Supply Boiler Return Front of Tank Tank Thermostat located under cover Dimensions A B C 4 ...

Страница 5: ...t 5 GPM 8 GPM 12 GPM MP 20 1 2 2 9 6 2 hd MP 32 1 6 3 8 8 0 hd MP 40 1 6 3 6 7 6 hd MP 50 1 8 4 2 8 8 hd Pressure Drop Graph 2 0 4 0 6 0 8 0 10 0 5 GPM 8 GPM 12 GPM Primary Flow Rate Head Loss FT HD PressureDrop Graph MP 20 MP 32 MP 40 MP 50 5 50 32 40 20 ...

Страница 6: ...134 95 156 111 140 000 134 95 156 111 165 000 168 119 195 000 Performance Data MP 32 Con nuous Draw Ra ngs Based Upon Boiler s Ability to Maintain 180º F Model MP 32 Circulator Flow GPM 5 5 8 8 12 12 DHW Temperature 120ºF 140ºF 120ºF 140ºF 120ºF 140ºF Boiler Hea ng Capacity in Btu Hr Output 45 000 106 78 106 78 60 000 134 97 134 97 75 000 162 116 162 116 95 000 168 120 188 134 198 141 115 000 168 ...

Страница 7: ...24 192 138 223 159 140 000 192 138 223 159 165 000 240 171 195 000 Performance Data MP 50 Con nuous Draw Ra ngs Based Upon Boiler s Ability to Maintain 180º F Model MP 50 Circulator Flow GPM 5 5 8 8 12 12 DHW Temperature 120ºF 140ºF 120ºF 140ºF 120ºF 140ºF Boiler Hea ng Capacity in Btu Hr Output 45 000 117 91 117 91 60 000 142 108 142 108 75 000 167 125 167 125 95 000 201 148 201 148 201 161 115 0...

Страница 8: ... water leakage The floor or area where the tank is installed must be capable of suppor ng the tank when filled with water Refer to the Specifica ons Table on the page 3 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Controls on this appliance could ignite vapors causing an explosion IV Installation Piping General a A...

Страница 9: ...changer Pressure Drop hd Domes c Water Connec on Sizes MP 20 5 GPM 1 2 3 4 MP 32 8 GPM 3 8 3 4 MP 40 12 GPM 7 6 3 4 MP 50 12 GPM 8 8 3 4 Tubing Type Flow Rate 10 GPM Flow Rate 15 GPM Type K 3 1 psi 6 5 PSI Type L 2 7 psi 5 7 psi Type M 2 3 psi 4 7 psi Fi ng Wrought Cast 90º Elbow 1 4 45º Elbow 1 2 Tee Run 1 2 1 2 Tee Branch 3 5 Long radius 90º Elbow 2 180º Bend 2 Gate Valve 1 ...

Страница 10: ...n the tank and the back ow device see piping diagram Refer to Thermal Expansion Tank manufacturer s lit erature for sizing and installa on informa on E Vacuum Breaker DHT recommends that a vacuum breaker be installed on the domes c piping to the heater The vacuum breaker protects the heater in the event that the tank pressure falls below atmos pheric pressure F Temperature Pressure Relief Valve T ...

Страница 11: ... or its own circulator The heater temperature is maintained by the use of an immersion type aq uastat The aquastat is installed into the im mersion well on the heater The aquastat operates in much the same way as a thermostat When the temperature falls inside the tank the set of contacts make close and when the temperature rises the contacts break open The aquastat should be ed into the boiler sys...

Страница 12: ...ntrols The con tacts open break on temperature rise when the tank reaches the set temperature Connect system wires to wiring block located under cover Auxiliary contacts Terminals C 1 purple brown for solar hea ng or other applica ons are normally closed and open break on temperature decrease This opera on is opposite most water heaters and should only be used for auxiliary equipment Set the tempe...

Страница 13: ... all other zones will stop opera on un l zone 6 is sa s ed When Zone 6 is not switched to priority all zones will operate independently Jumper Placement REMOVE the jumper between terminals ZC and ZR Connect termi nal ZC to ZC terminal on the aquastat control Connect terminal ZR to ZR terminal on the aquastat control Con rm polarity is con sistent between the boiler aquastat and the switching relay...

Страница 14: ...ed to the priority se ng and is ac vat ed all other zones will stop opera on un l zone 6 is sa s ed When Zone 6 is not switched to priority all zones will operate independently Jumper Placement The jumper should be placed between terminals ZC and ZR Con nect the isolated end switch to the aquastat on the boiler Power input Connect 120 volt as power input to terminals N and H Neutral wire to termin...

Страница 15: ...Wiring Diagrams 15 ...

Страница 16: ...Wiring Diagrams 16 ...

Страница 17: ...t water taps 4 A ach a hose to the drain valve located at the bo om of the heater and allow the heater to drain 5 Unscrew the anodes EXAMINE THE ANODES AND REPLACE IF THEY SHOW SIGNS OF DETERIORATION 6 Replacement of the Anodes The use or P T F E tape is recommended to ensure water ght connec on of the anodes Failure to inspect the anodes may result in premature failure of the heater and could voi...

Страница 18: ...ium indirect fired water heater services only one family unit in a multiple family dwelling provided that the term residential setting shall not include any usage of the Techtanium indirect fired water heater above 150 degrees Fahrenheit During the specified warranty period of the indirect fired water heater Diversified Heat Transfer Inc will repair or replace at its option without charge any indi...

Страница 19: ...da 12 Service calls not involving any malfunction or defects and maintenance in the ordinary course 13 Components of an indirect fired water heater which are not manufactured expressly for Diversified Heat Transfer such components are subject only to those warranties if any given by their manufacturers Diversified Heat Transfer does not adopt and has no responsibility for those warranties 14 Any T...

Страница 20: ... to the model and dimensions in the diagrams below When fastening the brackets to the wall make sure to use appropriate fasteners capable of suppor ng the full tank weight as speci ed below Please note that the tank may only be installed in the upright ver cal posi on Follow the piping and wiring instruc ons found in the installa on manual Optional Wall Mount Installation Instructions Models MP 20...

Отзывы: