- 2 - 

 

remembered in the MeterMatch.  Do the same process with the sender reading a value near the other 
end of its range, and you are done.  MeterMatch interpolates from these values to make the gauge 
read proportionately at values above, below, and between the calibration values.  If you know the 
resistance of your sender, you can also calibrate to common values, even without the sender being at 
that specific resistance.  The calibration points are typically near the ends of the gauge limits, but can 
be anywhere – for example you can have your only calibration points at 25% and 75%, and it will still 
work, but won’t be quite as accurate outside of those points. 

The basic process of having the gauge read properly from calibration points near each end of the 
range is fine for most applications, but you can be more sophisticated if you wish.  For example, what 
if your fuel tank is large at the bottom, and small at the top?  In this case, it won't read properly 
throughout the range.  MeterMatch provides two additional calibration points between the endpoints.  
So, in this case, you could have an additional calibration point where the tank changes size.   Another 
use for these points would be if your tank is cylindrical (like a truck fuel tank) so the gauge is 
inaccurate at both sides of center.  Here, you can add additional calibration points (for example at 
30% and 70%) and the accuracy is drastically improved 

The calibration data inside MeterMatch is stored internally in non-volatile memory that is maintained 
even when power is removed. 

 

 

 

Содержание MeterMatch MM-02

Страница 1: ...rMatch is wired between your sender sensor and your gauge It reads the resistance of the sender then based on the calibration values controls the current through the gauge to drive it to the desired reading It treats the input and output entirely separately so it doesn t care if the input to the gauge is scaled differently than the sender or even if the sender signal is reversed it can correct for...

Страница 2: ...ic process of having the gauge read properly from calibration points near each end of the range is fine for most applications but you can be more sophisticated if you wish For example what if your fuel tank is large at the bottom and small at the top In this case it won t read properly throughout the range MeterMatch provides two additional calibration points between the endpoints So in this case ...

Страница 3: ... Pin 3 To gauge output from MeterMatch Pin 2 Ground ensure that it is well grounded Pin 1 12V switched by ignition requires only a few mA Calibration Once wired it is necessary to calibrate your MeterMatch to tailor it to your sender and gauge As shipped default values are in place for switch positions 1 and 4 The rotary switch Ѳ positions are used as follows 0 Normal operation after calibration 1...

Страница 4: ...alibration point The MeterMatch reads the sender then saves that value along with the gauge signal into its internal memory The LED on MeterMatch will go out momentarily to indicate that the values are being saved then turn back on Repeat these steps but with the sender set to a position for the other end of measurement the rotary switch Ѳ to 4 Low Calibration Point and then use the Up Dn buttons ...

Страница 5: ...o which point you are setting Up Dn buttons to make gauge read the desired setting then Save When the Save button is pressed and the rotary switch Ѳ is not set to 0 MeterMatch will use the resistance value you just entered and then reset itself to back normal operation Calibration Checking and Enhancement Feel free to use a combination of these calibration methods For example you might initially c...

Страница 6: ...ary on older slower responding gauges but can come into play with more modern gauges that have less internal dampening This feature can be turned on and off with a power up sequence 1 remove power from the unit 2 set the rotary switch Ѳ to seven 3 press and hold the Save and Dn buttons and finally 4 reapply power to the unit and wait until the power up LED flashes indicating that power up is compl...

Страница 7: ...ed in what you make the gauge read with the Up Dn buttons As a result ensure that you have calibrated your gauge accurately rotary switch Ѳ positions 1 4 or your alarm will not be accurate either These points can also be erased using the same procedure as normal calibration points Depending on how your gauge works you may find that the low and high alarm set points are reversed in operation from w...

Страница 8: ...ns include a description of the fault to help facilitate repair Risk of damage loss during shipping becomes the customer responsibility once the product is delivered to a common carrier by TechnoVersions MeterMatchTM Specifications Size 1 85 x2 4 x0 93 Weight 1 2 Oz Connections 1x5 screw terminal strip accepting 14 22 AWG wires Input Power Voltage Range 7 Vdc 16 Vdc Sender Input Ohmmeter reading o...

Отзывы: