Method 1:

  Connect a resistor (available at places such as Radio Shack) of the desired value on the 

MeterMatch sender input pin (pin 4) to ground, then perform calibration at that point just as with the 
standard calibration process previously shown. 

Method 2:

 You can have MeterMatch calibrate to some internally stored resistance values.  To use 

these, do the following: 

1. Power up MeterMatch 

2. Set the rotary switch  

Ѳ

 

 to zero (normal operation) 

3. Press and hold the Save button.  The LED will illuminate. 

4. While the Save button is being held down, press the  Up button, the number of times shown in this 

table.  Each time you press the Up button the LED will blink the number of times that it has been 

pressed.  For example, after you have pressed it twice, it will blink twice.  You can start over at any 

time by releasing the Save button. 

Number of "Up" Button 

Pushes 

Sender Resistance Simulated 

(Ohms) 

10 

33 

73 

90 

180 

240 

 

5. Release the Save button, then use the standard calibration procedure: rotary switch  

Ѳ

 

  to which 

point you are setting, Up/Dn  buttons to make gauge read the desired setting, then Save.  When the 

Save button is pressed (and the rotary switch  

Ѳ

 

  is not set to 0), MeterMatch will use the resistance 

value you just entered, and then reset itself to back normal operation. 

Calibration Checking and Enhancement 

Feel free to use a combination of these calibration methods.  For example, you might initially calibrate 
to the published resistance values of your sender, then when the opportunity comes to improve 
accuracy, recalibrate a point.  Using the fuel gauge, for example, recalibrate the end-point when you 
run out of gas, or fill up the tank. Whenever you return to a position of the rotary dial, you can over-
write the data that was previously programmed.    

Resetting Data in MeterMatch 

If you would like to reset the MeterMatch back to factory defaults: (1) remove power from the unit, (2) 

set the rotary switch 

Ѳ

 

  to zero, (3) press and hold the  Save button, and finally (4) reapply power to 

the unit and wait until the power-up LED blinks, indicating that power-up is complete.  This presets 
the low and high values (switch positions 1 and 4) to values typical for after-market gauges, and sets 
other internal settings to defaults. 

Содержание MeterMatch MM-02

Страница 1: ...rMatch is wired between your sender sensor and your gauge It reads the resistance of the sender then based on the calibration values controls the current through the gauge to drive it to the desired reading It treats the input and output entirely separately so it doesn t care if the input to the gauge is scaled differently than the sender or even if the sender signal is reversed it can correct for...

Страница 2: ...ic process of having the gauge read properly from calibration points near each end of the range is fine for most applications but you can be more sophisticated if you wish For example what if your fuel tank is large at the bottom and small at the top In this case it won t read properly throughout the range MeterMatch provides two additional calibration points between the endpoints So in this case ...

Страница 3: ... Pin 3 To gauge output from MeterMatch Pin 2 Ground ensure that it is well grounded Pin 1 12V switched by ignition requires only a few mA Calibration Once wired it is necessary to calibrate your MeterMatch to tailor it to your sender and gauge As shipped default values are in place for switch positions 1 and 4 The rotary switch Ѳ positions are used as follows 0 Normal operation after calibration 1...

Страница 4: ...alibration point The MeterMatch reads the sender then saves that value along with the gauge signal into its internal memory The LED on MeterMatch will go out momentarily to indicate that the values are being saved then turn back on Repeat these steps but with the sender set to a position for the other end of measurement the rotary switch Ѳ to 4 Low Calibration Point and then use the Up Dn buttons ...

Страница 5: ...o which point you are setting Up Dn buttons to make gauge read the desired setting then Save When the Save button is pressed and the rotary switch Ѳ is not set to 0 MeterMatch will use the resistance value you just entered and then reset itself to back normal operation Calibration Checking and Enhancement Feel free to use a combination of these calibration methods For example you might initially c...

Страница 6: ...ary on older slower responding gauges but can come into play with more modern gauges that have less internal dampening This feature can be turned on and off with a power up sequence 1 remove power from the unit 2 set the rotary switch Ѳ to seven 3 press and hold the Save and Dn buttons and finally 4 reapply power to the unit and wait until the power up LED flashes indicating that power up is compl...

Страница 7: ...ed in what you make the gauge read with the Up Dn buttons As a result ensure that you have calibrated your gauge accurately rotary switch Ѳ positions 1 4 or your alarm will not be accurate either These points can also be erased using the same procedure as normal calibration points Depending on how your gauge works you may find that the low and high alarm set points are reversed in operation from w...

Страница 8: ...ns include a description of the fault to help facilitate repair Risk of damage loss during shipping becomes the customer responsibility once the product is delivered to a common carrier by TechnoVersions MeterMatchTM Specifications Size 1 85 x2 4 x0 93 Weight 1 2 Oz Connections 1x5 screw terminal strip accepting 14 22 AWG wires Input Power Voltage Range 7 Vdc 16 Vdc Sender Input Ohmmeter reading o...

Отзывы: