![TechnoVap CARMEN PLUS INOX Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/technovap/carmen-plus-inox/carmen-plus-inox_using-instruction_1070731011.webp)
11
electric outlet and proceed by replacing the drain cap (24). Once again plug the power cord (22) into the
electric outlet and activate the power switch only (8). It is recommended to activate also the command
switch (36) for minimum steam on the handgrip to release the air contained in the empty boiler. Wait for the
completed cycle of refilling from the pump (approx. 3 min.).
The maintenance of the boiler is completed; proceed with the using instructions as described in chapter 6.
We suggest to empty the water tank (16) completely if the machine will not be used for a long period of
time.
MAINTENANCE OF THE VACUUM CLEANER
The vacuum cleaner of the CARMEN PLUS INOX models does not require any specific maintenance.
MAINTENANCE OF THE ACCESSORIES
Grease occasionally joints on the accessories and hose extensions.
9.
BEFORE REFERRING TO THE TECHNICAL SERVICE
PROBLEM
POSSIBLE CAUSE
REMEDY
MACHINE DOES NOT PRODUCE
STEAM AND VACUUM DOES NOT
WORK.
LACK OF POWER.
MAKE SURE PLUG IS WELL INSERTED (7)
AND THAT THERE IS MAIN POWER TO THE
OUTLETS.
THE RED "LOW WATER" INDICATOR
(11) LIGHTS UP.
ALL THE WATER HAS BEEN CONSUMED.
REFILL THE WATER TANK (16) WITH CLEAN
WATER.
THERE IS NO INJECTION OF
DETERGENT.
ALL THE DETERGENT FROM THE
DETERGENT TANK (15) COULD HAVE BEEN
CONSUMED.
CONTROL THE LEVEL IN THE DETERGENT
TANK (15). IF NECESSARY, REFILL THE
DETERGENT TANK (15) AS DESCRIBED IN
THE INSTRUCTIONS.
SUCTION POWER IS MISSING.
A. LACK OF POWER TO THE VACUUM
CLEANER.
B. THE VACUUM TUBE IS OBSTRUCTED.
C. THE VACUUM DRUM (4) IS FULL OF
WATER.
A.
MAKE SURE THE SWITCH (2) IS ON
AND THE PLUG (7) IS WELL INSERTED.
B.
CLEAN TUBE AND ACCESSORY USED.
C.
EMPTY THE VACUUM DRUM 4.
WATER LEAKS THROUGH THE
CONNECTIONS OF THE
ACCESSORIES.
CHECK THE WEAR OF THE
O-RING.
CLEAN AND LUBRICATE THE O-RING WITH
GREASE.
IF NECESSARY, REPLACE WITH ONE SPARE
SUPPLIED.
STEAM DOES NOT COME OUT.
A. BOILER HAS NOT REACHED YET THE
OPERATIONAL PRESSURE (GREEN
LIGHT (10) IS OFF).
B. STEAM COMMAND SWITCHES (36-37)
ARE OFF.
C. THE STEAM COMMAND SWITCH (34)
HAS NOT BEEN USED.
A.
WAIT A FEW MINUTES.
B.
SWITCH ON THE STEAM COMMAND
SWITCHES (36-37).
C. USE THE STEAM COMMAND
SWITCH (34) TO ACTIVATE THE
STEAM FLOW.
DROPS OF WATER COME OUT OF
THE ACCESSORIES.
AT BEGINNING OF WORK WATER
CONDENSES IN THE TUBES AND
ACCESSORIES DUE TO THE DIFFERENCE
IN TEMPERATURE.
AFTER A FEW MINUTES OF USE THIS
PROBLEM WILL CEASE. IF IT CONTINUES,
PROCEED TO THE CLEANING OF THE
BOILER.
ACCESSORIES DO NOT FIT
PERFECTLY.
THERE IS DIRT BUILD UP IN THE JOINTS
AND LOCK/RELEASE LATCHES (40).
CLEAN AND LUBRICATE THE JOINTS.
Содержание CARMEN PLUS INOX
Страница 1: ...1 CARMEN PLUS INOX USING INSTRUCTION ENGLISH ...
Страница 5: ...5 5 TECHNICAL DRAWINGS CARMEN PLUS INOX ...
Страница 6: ...6 ACCESSORIES ...
Страница 7: ...7 ...