![TechnoVap CARMEN PLUS INOX Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/technovap/carmen-plus-inox/carmen-plus-inox_using-instruction_1070731010.webp)
10
Turbo lance steam/vac (42): to be used by itself with the small round brushes (43-46, 49) or with steam
plunger (47) and steam scraper (48) according to the cleaning job to be executed.
If necessary, attach the extension tubes (41) and lock them into place using the clamping units (40) in
BLOCK position. Only one tube may be used if desired.
When finished cleaning, it is recommended to vacuum approximately 2-3 liters of clean water to rinse the
inside of the hose (33) and the suction conduits. Wash and dry all accessories used. Remove the vacuum
drum (4) and, after emptying and rinsing it, let it dry before storing it away.
OPERATING THE CARMEN PLUS INOX WITH KIT JULY
Insert steam plug (32) into the steam outlet (23) found on the front of the machine. Push until the latch (31)
locks into place.
Activate the power switch (8) and the boiler switch (9) in and wait approximately 4 minutes until the "ready
steam" indicator (10) lights up indicating the boiler has reached operating pressure. The command
switches (36-38) located on the handle should be in the OFF position.
Positioning the switches (36 and 37) on the handgrip will regulate the steam flow as follows: switch (36)
minimum flow, switch (37) medium flow, switches (36 and 37) maximum flow. Use the steam command
switch to activate the steam flow.
Insert the steam lance by sliding the latch to the OPEN position, lock into place and then slide the latch into
BLOCK position.
Follow the same procedure in attaching the rectangular brush (72) or the triangular brush (74) which can
be covered with an absorbing cloth by using the gripper to hold the cloth in place. This is a recommended
use to clean delicate surfaces (such as precious wood for ex.) or vertical surfaces (in tiles for ex.) etc. The
cloth is acting as dirt "extractor" in this case.
8.
MAINTENANCE
ATTENTION
DISCONNECT FROM ELECTRICAL POWER SUPPLY BEFORE CARRYING OUT USER
MAINTENANCE. IT IS RECOMMENDED THAT BOILER MAINTENANCE IS CARRIED OUT WHEN THE
EQUIPMENT HAS COOLED DOWN. (SWITCHED OFF FOR AT LEAST 5 HOURS)
MAINTENANCE OF STEAM GENERATOR
ELIMINATING SCALE RESIDUE FROM THE BOILER
We suggest cleaning the boiler after every 100 hours of use, or also if the machine has remained unused
for a long period of time.
Fill the water tank (16) (3 liters), placing a recipient container under the machine and remove the boiler
drain cap (24) underneath the machine. Then switch on the machine activating the power switch only (8)
(the boiler switch (9) has to be in OFF position). Wait until the "low water" indicator (11) lights up which
indicates that the internal cleaning of the boiler has been completed. Unplug the power cord (22) from the