Turbo  lance  steam/vac  (42):  to  be  used  by  itself  with  the  small  round  brushes  (43-46,  49)  or  with  steam 

plunger (47) and steam scraper (48) according to the cleaning job to be executed. 

If  necessary,  attach  the  extension  tubes  (41)  and  lock  them  into  place  using  the  clamping  units  (40)  in 

BLOCK position. Only one tube may be used if desired.  

When finished cleaning, it is recommended to vacuum approximately 2-3 liters of clean water to rinse the 

inside of the hose (33) and the suction conduits. Wash and dry all accessories used. Remove the vacuum 

drum (4) and, after emptying and rinsing it, let it dry before storing it away. 

 

OPERATING THE CARMEN PLUS INOX WITH KIT JULY 

Insert steam plug (32) into the steam outlet (23) found on the front of the machine. Push until the latch (31) 

locks into place. 

Activate the power switch (8) and the boiler switch (9) in and wait approximately 4 minutes until the "ready 

steam"  indicator  (10)  lights  up  indicating  the  boiler  has  reached  operating  pressure.  The  command 

switches (36-38) located on the handle should be in the OFF position. 

Positioning  the  switches  (36  and  37)  on  the  handgrip  will  regulate  the  steam  flow  as  follows:  switch  (36) 

minimum  flow,  switch  (37)  medium  flow,  switches  (36  and  37)  maximum  flow.  Use  the  steam  command 

switch to activate the steam flow. 

Insert the steam lance by sliding the latch to the OPEN position, lock into place and then slide the latch into 

BLOCK position. 

Follow  the  same  procedure in attaching the rectangular brush (72) or the triangular  brush (74)  which can 

be covered with an absorbing cloth by using the gripper to hold the cloth in place. This is a recommended 

use to clean delicate surfaces (such as precious wood for ex.) or vertical surfaces (in tiles for ex.) etc. The 

cloth is acting as dirt "extractor" in this case. 

 

8. 

MAINTENANCE 

ATTENTION 

DISCONNECT  FROM  ELECTRICAL  POWER  SUPPLY  BEFORE  CARRYING  OUT  USER 

MAINTENANCE. IT IS RECOMMENDED THAT BOILER MAINTENANCE IS CARRIED OUT WHEN THE 

EQUIPMENT HAS COOLED DOWN. (SWITCHED OFF FOR AT LEAST 5 HOURS) 

 

MAINTENANCE OF STEAM GENERATOR 

ELIMINATING SCALE RESIDUE FROM THE BOILER 

We suggest cleaning the boiler after every 100 hours of use, or also if the machine has remained unused 

for a long period of time. 

Fill  the  water  tank  (16)  (3  liters),  placing  a  recipient  container  under  the  machine  and  remove  the  boiler 

drain  cap  (24)  underneath  the  machine.  Then  switch on the machine  activating the power  switch only (8) 

(the  boiler  switch  (9)  has  to  be  in  OFF  position).  Wait  until  the  "low  water"  indicator  (11)  lights  up  which 

indicates that the internal cleaning of the boiler has been completed. Unplug the power cord (22) from the 

Содержание CARMEN PLUS INOX

Страница 1: ...1 CARMEN PLUS INOX USING INSTRUCTION ENGLISH ...

Страница 2: ...NTERS AND MUST NOT BE LEFT IN THE ENVIRONMENT SUBSTANCES SUCH AS OIL FOR MOTORS DIESEL OIL PETROL MUST NOT BE LEFT IN THE ENVIRONMENT AND MUST BE RECICLED IN THE PROPER RECICLING CENTERS ACCORDING TO THE ENVIRONMENTAL REGULATIONS BEFORE USING THE STEAM GENERATOR READ AND FOLLOW THIS INSTRUCTION MANUAL IT IS RECOMMENDED TO KEEP THIS INSTRUCTION MANUAL TO CONSULT IT LATER OR TO GIVE IT TO THE FOLLOW...

Страница 3: ...vice has been compromised and the safety valve has been involved as to limit the boiler s internal pressure It is recommended not to use the machine immediately unplug the machine from the power feeding and call the service center MUD DRAIN FROM THE BOILER If you are not acquainted with the hardness level of the used water it is recommended to proceed with the boiler cleaning according to the proc...

Страница 4: ...ule and to consult the supplier 3 TECHNICAL CHARACTERISTICS To verify the technical data of your model consult the plate under the appliance 4 PREFACE Dear Client We would like to congratulate you on your choice With the goal of improving and continually updating production by always offering innovative products TECNOVAP has studied designed and created the CARMEN PLUS INOX model a combined machin...

Страница 5: ...5 5 TECHNICAL DRAWINGS CARMEN PLUS INOX ...

Страница 6: ...6 ACCESSORIES ...

Страница 7: ...7 ...

Страница 8: ...optional 21 Electric socket for vacuum cleaner 60 Upholstery nozzle optional 22 Power cord 61 Insert squeegee squeegee 145 mm opt 23 Steam outlet 62 Insert squeegee brush 145 mm optional 24 Boiler drain cap 63 Insert brush brush 145 mm optional 30 Vacuum hose coupler 70 Steam hose handgrip optional 31 Locking latch steam plug 71 Steam lance optional 32 Steam plug 72 Rectangular brush optional 33 S...

Страница 9: ...ine Push until the latches 5 and 31 lock into place Activate the power switch 8 and the boiler switch 9 in for the production of steam and wait approximately 4 minutes until the green ready steam indicator 10 on the command switch lights up indicating the boiler has reached operating pressure The switches 36 37 and 38 located on the handle should be in OFF position Positioning the switches 36 and ...

Страница 10: ...d 37 maximum flow Use the steam command switch to activate the steam flow Insert the steam lance by sliding the latch to the OPEN position lock into place and then slide the latch into BLOCK position Follow the same procedure in attaching the rectangular brush 72 or the triangular brush 74 which can be covered with an absorbing cloth by using the gripper to hold the cloth in place This is a recomm...

Страница 11: ...HERE IS NO INJECTION OF DETERGENT ALL THE DETERGENT FROM THE DETERGENT TANK 15 COULD HAVE BEEN CONSUMED CONTROL THE LEVEL IN THE DETERGENT TANK 15 IF NECESSARY REFILL THE DETERGENT TANK 15 AS DESCRIBED IN THE INSTRUCTIONS SUCTION POWER IS MISSING A LACK OF POWER TO THE VACUUM CLEANER B THE VACUUM TUBE IS OBSTRUCTED C THE VACUUM DRUM 4 IS FULL OF WATER A MAKE SURE THE SWITCH 2 IS ON AND THE PLUG 7 ...

Страница 12: ...rollo della conformità alle sopraindicate direttive sono stati seguiti i seguenti standard For the checking of conformity to the above directives the following standards have been used Riferimento alle norme armonizzate Reference to harmonized standards EN 60335 1 EN 60335 2 2 EN 60335 2 79 EN 60335 2 3 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 PESCANTINA VERONA ITALY 02 02 2010 FRANCHINI Gi...