Edition:10/14
12
Manual Storage Heater TTS with electronic control
GB
This is repeated until all the bricks have
been installed.
After removing any waste, dust or other particles from the interior of the heater, the panels
can be refitted in the reverse order, i.e.
1. inside front panel
2. outside front panel
3. air-outlet grille.
Connection of Supply Cables
Warning! THIS APPLIANCE MUST BE EARTHED!
Only heat resisting cable shall be used. The wire in the mains cable will be coloured
according to the following code:
Green and Yellow:
Earth
Brown:
Live
Blue:
Neutral
The electrical wiring requires two supply cables. Ensure the cable is appropriate for the
heater rating.
1. Feed the two supply cables (three if automatic charge control is used) in from the rear of
the heater through the cable clamp and to the terminal block.
2. Storage Element Supply - Connect the live phase cables to the terminals marked L1, L2
and L3 and connect the neutral to one of the terminals marked N.
3. Fan Supply - This supply is connected into the terminal strip located below the element
terminal block. Connect the live supply to the terminal marked LE and the neutral supply
to the terminal marked N.
4. Earth Connection - Ensure the earth cables are securely fixed to the earthen screws
located at the bottom of both terminal blocks.
5. Ensure all cables are firmly connected to the terminal blocks.