![Technosoft iPOS4808 BX-CAN-STO Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/technosoft/ipos4808-bx-can-sto/ipos4808-bx-can-sto_technical-reference_1070597032.webp)
Technosoft 2017
32
iPOS4808 BX-CAT-STO Technical Reference
3.6
Electrical Specifications
All parameters measured under the following conditions (unless otherwise specified):
T
amb
= 0…40
°
C, V
LOG
= 24 V
DC
; V
MOT
= 48V
DC
; Supplies start-up / shutdown sequence: -
any-
Load current (sinusoidal amplitude / continuous BLDC,DC,stepper) = 8A iPOS4808
3.6.1
Operating Conditions
Min.
Typ.
Max.
Units
Ambient temperature
0
+40
ºC
Ambient humidity
Non-condensing
0
90
%Rh
Altitude / pressure
Altitude (referenced to sea level)
-0.1
0 ÷ 2.5
2
Km
Ambient Pressure
0
2
0.75 ÷ 1
10.0
atm
3.6.2
Storage Conditions
Min.
Typ.
Max.
Units
Ambient temperature
-40
105
ºC
Ambient humidity
Non-condensing
0
100
%Rh
Ambient Pressure
0
10.0
atm
ESD capability (Human body model)
Not powered; applies to any accessible part
±
0.5
kV
Original packaging
±
15
kV
3.6.3
Mechanical Mounting
Min.
Typ.
Max.
Units
Airflow
natural convection
, closed box
3.6.4
Environmental Characteristics
Min.
Typ.
Max.
Units
Size ( Length x Width x Height )
Without mating connectors
103 x 71 x 16.4
mm
~4.06 x 2.8 x 0.65
inch
With recommended mating connectors.
109 x 79 x 19.5
mm
~4.3 x 3.1 x 0.77
inch
Weight
Without mating connectors
125
g
Power dissipation
Idle (no load)
3.4
W
Operating
8.5
W
Efficiency
98
%
Cleaning agents
Dry cleaning is recommended
Only Water- or Alcohol- based
Protection degree
According to IEC60529, UL508
IP20
-
3.6.5
Logic Supply Input (+V
LOG
)
Min.
Typ.
Max.
Units
Supply voltage
Nominal values
9
36
V
DC
Absolute maximum values, drive operating but outside
guaranteed parameters
8
40
V
DC
Absolute maximum values, continuous
-0.6
42
V
DC
Absolute maximum values, surge
(duration
≤
10ms)
†
-1
+45
V
+V
LOG
= 12V
130
mA
+V
LOG
= 24V
90
280
+V
LOG
= 40V
85
3.6.6
Motor Supply Input (+V
MOT
)
Min.
Typ.
Max.
Units
Supply voltage
Nominal values
11
50
V
DC
Absolute maximum values, drive operating but outside
guaranteed parameters
9
52
V
DC
Absolute maximum values, continuous
-0.6
54
V
DC
Absolute maximum values, surge
(duration
≤
10ms)
†
-1
57
V
Supply current
Idle
1
5
mA
Operating
iPOS4808
-20
±8
+20
A
Absolute maximum value, short-circuit condition
(duration
≤
10ms)
†
iPOS4808
26
A
1
Operating temperature at higher temperatures is possible with reduced current and power ratings
2
iPOS4808 can be operated in vacuum (no altitude restriction), but at altitudes over 2,500m, current and power rating are reduced
due to thermal dissipation efficiency.
3
In case of forced cooling (conduction or ventilation) the spacing requirements may drop down to mechanical tolerances as long as
the ambient temperature is kept below the maximum operating limit