© Technosoft 2013
16
IO-iPOS4808 Technical Reference
OFF
Connect a pull-up/pull-
down 22K Ω resistor
(depending on jumper 13) to AxisID2
15
EncA/Sin termination
0
Do no
t connect a 120Ω resistor between
A+/Sin+ and A-/Sin-
1
Connect a 120Ω resistor between A+/Sin+
and A-/Sin-
16
Fdbk. 5/10
1-2
Select 0…+5 V Feedback
2-3
Select -
10…+10 V Feedback
17
EncB/Cos termination
0
Do no
t connect a 120Ω resistor between
B+/Cos+ and B-/Cos-
1
Connect a 120Ω resistor between B+/Cos+
and B-/Cos-
18
EncZ termination
0
Do no
t connect a 120Ω resistor between Z+
and Z-
1
Connect a 120Ω resistor between Z+ and Z
-
19
AutoRun
0
Enable AutoRun (normal operation)
1
Disable AutoRun
20
CAN termination
0
Do not connect a CAN terminator
1
Connect a CAN terminator (120Ω resis
tor)
21
CAN supply
0
Do not connect CAN Supply to +V
LOG
1
Connect CAN Supply to +V
LOG
22
Reserved
-
Do not connect.
23
Reserved
-
Do not connect.