RECLINE EXCITE: Service & Maintenance Manual - rev. 1.1
Page 6.16
6.9. THERE IS NO HEART RATE SIGNAL
6.9.1. R
ICEVITORE TELEMETRICO
HFU
La macchina mostra questo errore se il ricevitore non funziona o se non alimentato dalla scheda
digital plan.
THERE IS NO HR
SIGNAL
Is the supply v oltage correct at
the input to the receiv er?
Is the supply v oltage correct at
the output of the digital plan
board?
Replace the receiv er
Replace CBQ-28 cable
1
2
YES
NO
YES
Replace digital plan board
NO
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Place the tester probes across pins 1 and 3 of connector CN1 of the receiver. The measured
value should be +5 Vdc.
(2)
As for step (1) but across pins 1 and 8 of connector CN11 on the digital plan board.