JOG NOW : Service & maintenance manual - rev. 6.2
Page 6.3
The tests are divided into two groups: Automatic and Manual, and the prompt for a choice appears
immediately on accessing the troubleshooting menu.
6.1.1.
A
UTOMATIC
T
EST
The tests grouped under this section conduct checks on the machine’s operation in a fully automatic
manner. After selecting the desired test using the
+
and – effort level keys, press
ENTER
to initiate
the test and then await the result. Press
ENTER
again to continue, and use the
CLEAR
key to
return to the higher menu level, holding it down for a few seconds. The various tests are described
below.
6.1.1.1.
I2C Devices Test
The I2C Devices test checks the communication following the 32K and 256K. The test can have
outcomes:
•
“Test Successful, press Enter to continue”: Signifies that the transmission and reception of
data packets between the I2C devices and the display board was completed successfully.
•
“EEPROM Error, press Enter to continue”: Signifies that the display board is having
problems communicating with its memories.
6.1.1.2.
Up-Down Test
The Up-Down test checks whether the number of pulses output by the encoder corresponds to the
values of the Up-Down table stored in the low kit. During the test, the machine incline is moved
from 0 to 15% (
for 700 models
) and from 0 to 18% (
for 900 models
) and then back to 0. Each
incline position is converted into a number of pulses and compared with the value in the Up-Down
table.
Two messages appear during the test:
•
“Incline =15%”: This message appears during the upward movement, when the machine
incline reaches 15%.
•
“Incline =3%”: This message appears during the downward movement, when the machine
incline reaches 3%.
The test can have two outcomes:
•
“DC Error (Up/Down), press Enter to continue”: The message indicates that the values do not
correspond. The specific message (Up or Down) indicates whether the error occurred during
the upward (Up) or downward (Down) movement of the test.
•
“Test Successful, press Enter to continue”: This message indicates that the test was completed
without errors.
Содержание Jog Now Excite+ 700
Страница 2: ......
Страница 4: ...JOG NOW Excite Service maintenance manual rev 6 2...
Страница 29: ...JOG NOW Excite Service maintenance manual rev 6 2 Page 2 17 UNITY Version...
Страница 31: ...JOG NOW Excite Service maintenance manual rev 6 2 Page 2 19 UNITY Version...
Страница 186: ...JOG NOW Excite Service maintenance manual rev 6 2 Page 8 6 Page intentionally left blank...
Страница 222: ...JOG NOW Excite Service maintenance manual rev 6 2 Pagina 12 2 Blank page...
Страница 224: ...JOG NOW Excite Service maintenance manual rev 6 2 Pagina 13 2 Blank page...
Страница 226: ......
Страница 227: ......