JOG NOW : Service & maintenance manual - rev. 6.2
Page 3.30
3.24.3.2.
The signals involved
The following signals are involved in the control:
Emergency 2 signal:
•
HK: (Pin 15 on CN17).
Emergency 1 signal (With ADAPTER cable):
•
LK – ALEWin ( Pin 8 on J3).
RS-485 signal: is a digital signal exchanged by HK and LK.
•
LK: (Pin 1-5 on J3)
•
HK: (Pin 5-13 on CN17)
RESET Signal: This is the signal generated by HK, sent to the LK to signal restoring of normal
status after an emergency condition. This signal is 0 VDC in normal conditions and becomes 12
VDC for a few seconds when the user presses a key:
•
LK: (Pin 10 su J3);
•
HK: (Pin 7 su CN17).