JOG EXCITE: Service & Maintenance Manual - rev. 1.1
Page 9.16
9.2.6.1.
Low kit version
This function displays the inverter firmware version. To access this menu, when the LED display
shows:
LOW KIT VERSION
press
ENTER
, the following message appears:
H:x L:x B:x
Which identifies the firmware version.
9.2.6.2.
Config. registers
This function displays the parameter values of type b, C, D, F, P, H and S. To access this menu,
when the LED display shows:
CONFIG REGISTERS
press
ENTER
, the following message appears:
ADDRESS: X
where X is the address identifying an AT driver parameter, as detailed in the tables at the end of the
paragraph.
Press
ENTER
to change the address and select a different parameter, or press + to read the value of
the currently selected parameter, the following message will appear:
READ FROM LOW KIT ?
press
ENTER
to load the parameter value, the following message will appear:
VALUE: Y
press
ENTER
to begin editing the parameter value. When finished, press + and the following
message will appear:
WRITE TO LOW KIT ?
press
ENTER
to confirm writing the changes to the low kit; at the end of this operation the
following message reappears:
ADDRESS: X
Although the changes made to the parameters come into effect immediately, they are not
automatically stored in permanent memory; this requires a specific write operation
effected using the command C-0: at address 800 write the value “1”, following the
detailed instructions provided in paragraph 9.2.6.2 “Config. registers”.
To return to the upper menu level press
CLEAR
for a few seconds.