Electrical installation
The electrical installation to which the machine is connected must be in compliance with standards
and the electrical work required must be carried out by a qualified electrician. An efficient electrical
installation with adequate earth is of primary importance to ensure trouble-free operation of your
machine.
We recommend installation of a suitable wall mounted differential circuit-breaker. See table (
A
) for power
supply and absorption data
Check that the power supply is correct for the machine details as indicated on the plate (see page
6
).
The machine’s power cable has
4
wires: the
yellow/green
wire is the earth
– the other three are the
three
phases
.
Table (A)
FREEZER 200/1
220 V
50 Hz
220 V
60 Hz
200 V
50/60Hz
400 V
60 Hz
380 V
50 Hz
415 V
50Hz
Total power
kW.
8,9
8,9
8,9
Max absorption
A.
34
22
22
Power cable
N° of wires and cross section
4 x 6
mm²
4 x 6
mm²
4 x 2,5
mm²
4 x 2,5
mm²
4 x 2,5
mm²
TECHNOGEL DISCLAIMS ALL RESPONSIBILITY FOR DAMAGE ARISING FROM INCORRECT
ELECTRICAL INSTALLATION OR FAULTS IN THE POWER SUPPLY