Programming
User Manual -
TP4-20
3-10
z
Disabling exclusion (
dis
ables the code from the exclusion of zones (manual or
automatic) upon arming. In case of arming in presence of open zones, these are
activated and release the alarm.)
On the display is viewed current programming:
[ ]
Function disabled
[ # ]
Function enabled
Commands available
+
wy
to select the function
+
#
to enable the function
+
*
to disable the function
+
CL-EX
to confirm and quit
3.1.8
PROGRAMMING OF THE KEYS
From the master programming menu select the submenu keys.
The control panel recognizes up to 16 electronic keys to be used for arming/disarming
or bypass of the programs associated.
SELECTION OF THE KEY
+
wy
to select the key to be programmed (1 to 16)
+
#
to confirm the selection
In the key menu the following parameters can be programmed:
z
Access periods (association of the access periods (1 to 2) during which the key
selected is to be enabled, i.e. recognized by the control panel)
z
Programs (association of the programs (1 to 4 -
max. 3
) the code selected is to
act on)
z
Attribute (programming of the function of the key)
z
Learning (reading of the code of the key).
Commands available
+
wy
to select the parameter to be programmed
+
#
to confirm the selection
ACCESS PERIODS
The access periods (1 to 2) limit the period of recognition of the key selected by the
control panel. Outside the access periods associated the introduction of the key will
have no effect.
On the display is viewed current programming:
[ ]
Access period not associated to the key selected
[ # ]
Access period associated to the key selected
Commands available
+
wy
to select the access period
+
#
to associate the access period to the key selected
+
*
to undo the association
+
CL-EX
to confirm and quit
PROGRAMS
The association key-programs determines the programs (1 to 4) the key is to act on,
i.e. the programs it may arm/disarm or partset.
On the display is viewed current programming:
[ ]
Program not associated to the key selected
[ # ]
Program associated to the key selected
Commands available
+
wy
to select the program
+
#
to associate the program to the key selected
+
*
to undo the association
+
CL-EX
to confirm and quit
ATTRIBUTE
The following functions can be programmed:
z
Bypass (enables the key for the bypass of the programs associated)
z
Bypass general alarms (enables the key for arming of the system in presence of
general alarms, i.e. tamper, low battery, power failure, supervision, trouble
modules)
z
Confirmation of disarming (hold-up block, i.e. on disarming with electronic key a
timer (programmable by the installer) is activated on rundown of which a hold-up
alarm is released unless a valid user code is entered on one of the consoles
connected)
z
Automatic abort on disarming (enables the key for the automatic block of the
alarm call cycles of all the active telephone channels and those waiting on
disarming of the system)
Key 01 2
Acc. periods
Acc. periods
Period 01 [ # ]
Key 01 3
Programs
Programs
Program 01 [ # ]
Menu 12
Keys
Keys 1
Key 01
Key 01 4
Attribute
Содержание TP4-20
Страница 4: ...IV User Manual TP4 20...
Страница 6: ...II Preface UserManual TP4 20...
Страница 10: ...Index UserManual TP4 20 4...
Страница 42: ...Programming User Manual TP4 20 3 16 3 2 STANDARD USER MENU STANDARD USER PROGRAMMING MENU...
Страница 44: ...Programming User Manual TP4 20 3 18...
Страница 47: ...TP4 20 User Manual Control by Console 4 3 OPERATIONS EXECUTABLE WITHOUT CODE...