Signaling
User Manual -
TP4-20
2-2
2.1.2
PROGRAM ALARM LED
(RED)
Program alarm is detected only if the control panel is armed.
The red program alarm led produces the following signaling:
z
Led blinking = alarm active
The led starts blinking upon detection of an alarm on one of
the zones included in the program and continues blinking
during the entire alarm time. Depending on programming, the
indoor and/or outdoor sirens and/or the logic outputs OUT1-
and OUT2- are activated, too.
Once the alarm has stopped, the led is switched off.
z
Led on = alarm stored (alarm memory)
The led becomes lit on disarming of the control panel, and is
lit until the program is armed again.
z
Led off = no alarm
Program alarms are stored in the event buffer of the control panel
with indication of date and time of beginning and end of alarm.
SIGNALING ON DISPLAY
In case of program alarm, beside led signaling, on the display is
viewed the name of the zone that has released the alarm.
2.1.3
GENERAL CONTROL LED
(YELLOW)
The yellow general control led signals open zones.
CONTROL PANEL IN STAND-BY
z
Led blingking = one or more zones open
Opening of a zone does not cause any alarm release.
z
Led off = zones ok
CONTROL PANEL ARMED
z
Led blingking = one or more zones open
If one of these zones is contained in a program armed, the
alarm devices programmed are activated.
z
Led off = zones ok
To identify the open zones consult the event buffer of the control
panel.
2.1.4
TAMPER ALARM LED
(RED)
The red tamper led signals tamper and zone tamper alarm. These
alarms are direct and are always detected, even if the control
panel is in stand-by, in case of:
z
Opening of the tamper input (ZT)
z
Opening of the tamper contact of a console or a module
connected via serial bus
z
Transection of the connection cable of a detector (zone
tamper alarm)
Zone tamper alarm is detected only by the inputs with
double end-of-line resistor contact (B24).
z
Short circuit on the connection cable of a detector
z
Opening of the tamper contact of a detector
CONTROL PANEL ARMED
z
Led blinking = alarm active
The led starts blinking upon detection of the alarm and
continues blinking during the entire tamper alarm time. The
indoor and outdoor sirens are activated, too.
Once the alarm has stopped it becomes lit.
z
Led on = alarm stored (alarm memory)
CONTROL PANEL IN STAND-BY
z
Led blinking = alarm active
The led starts blinking upon detection of the alarm and
continues blinking during the entire tamper alarm time. The
indoor sirens are activated, too.
Once the alarm has stopped it becomes lit.
z
Led on = alarm stored (alarm memory)
To identify the zone in alarm or the kind of tamper alarm
consult the event buffer of the control panel.
ALARM
Extension Z2
Содержание TP4-20
Страница 4: ...IV User Manual TP4 20...
Страница 6: ...II Preface UserManual TP4 20...
Страница 10: ...Index UserManual TP4 20 4...
Страница 42: ...Programming User Manual TP4 20 3 16 3 2 STANDARD USER MENU STANDARD USER PROGRAMMING MENU...
Страница 44: ...Programming User Manual TP4 20 3 18...
Страница 47: ...TP4 20 User Manual Control by Console 4 3 OPERATIONS EXECUTABLE WITHOUT CODE...