ACCESS/A A711 L-Series Installation & Operating Instructions 09RE416
Technisonic Industries ltd. Copyright 1996, 1997, 2010, 2011 BY TiL ALL RIGHTS RESERVED Page 2-24
2.15
POST-INSTALLATION ADJUSTMENTS
After installation, the A711L may require adjustment of some functions to compensate for airframe
and equipment specific issues, and to suit user tastes. Locations of these adjustments are as shown
in section 2.14. All are 20-turn miniature trimpots, except as noted. “MUSIC” input may be for any
entertainment audio feed, such as CD, tuner, etc.
Note, back adjustments (alerting) are NOT normally field adjusted, unless required. The 37
Pin connector (not required for this test) above these adjustments may be removed to
facilitate the adjustment of these alerting pots. Be extremely careful of any adjustments to
these settings, as incorrect levels will be highly problematic in the airframe. These are
normally bench adjustments.
The unit adjustments are as follows:
TOP – PA Adjustments –Direct Level
Adjustment Name
Location
Procedure/purpose
Notes
Direct Input Level
Top
Adjusts “Direct” input J210-3/22, an
un-switched input, set as required.
Often not used in installation.
Preset, Set to desired level,
if required
PA Monitor Brightness
Top
OPTIONAL, sets PA level LED.*
Set with remote PA to give
brightness desired for full
output
PA Flash Depth
Top
Sets the dim/bright ratio of the green
PA mode annunciator LED. *
Select PA, and set to suit.
This is the visual warning of
PA operation.
PA Mode Tick Level
Top
Selected by internal jumper, can
send an audible tick at the flash rate
during PA operation for pilot
warning.
Select PA, and set to suit.
Optional feature, internal
jumper must be set to
enable.
PA Flash Rate
Top
Sets the green PA mode
annunciator flash rate. *
Select PA, and set to suit.
This is the visual warning of
PA operation.
•
(*) Not altered by the external annunciator control.