9
Satisfaction guaranteed on all our CNC tooling solutions | www.techniksusa.com
ADJUSTING COOLING TIME
• The descending speed of the toolholder is adjusted by the speed
flow control on Port B of the air valve.
• If the descending speed is set too slow, there may not be adequate
cooling time.
• On the Setup screen, adjust the “Quench Time” to account for poor
cooling due to a slow descending speed.
ADJUSTING DRYING TIME
• The ascending speed of the toolholder is adjusted by the speed
flow control on Port A of the air valve. If the ascending speed is
too high, there may not be adequate time for the toolholder to dry.
• On the Setup screen, adjust the “Lower Dry Time” so the lower dry
air valve shuts off after the pedestal passes the lower nozzles.
• Adjust the “Upper Dry Time” so the upper dry air valve shuts off
when the pedestal reaches the top position.
• If the coolant becomes contaminated it will need to be replaced.
• Begin by draining the coolant through the Coolant Drain Valve.
Then flush the Quench tank and close the drain valve. Be sure
to dispose of the contaminated coolant following the appropriate
environmental guidelines in the back of this manual.
• Remove, clean and replace the strainer from the pump inlet hose
in the tank.
• Add 1 gallon CIMTECH 310 (Techniks Part No. 00500-C) to 20
gallons fresh water. Refill the tank with clean approved coolant
and run a Quench cycle to verify coolant is flowing properly.
REMINDER:
Always use the supplied insulated glove and exercise caution when handling toolholders. All personnel should be
clear of the machine before starting the tool change or Quench cycle. Never touch any toolholders that are not properly cooled.
The Quenching Time and coolant flow must be set to provide adequate cooling time to protect personnel from injury caused by
improperly cooled toolholders.
00500 QUENCHER SYSTEM ADJUSTMENTS
A ports
B ports
IN CASE OF CONTAMINATED COOLANT
Note: The drying cycle is not meant to remove all
of the moisture from the toolholder. The drying
cycle should be adjusted to remove most of the
dripping coolant from the toolholder.
Содержание 00500 ShrinkPRO Quencher
Страница 27: ...27 Satisfaction guaranteed on all our CNC tooling solutions www techniksusa com MSDS Sheets for CIMTEC Coolant ...
Страница 28: ...28 Phone 800 597 3921 or 317 803 8000 Fax 317 803 8001 MSDS Sheets for CIMTEC Coolant ...
Страница 29: ...29 Satisfaction guaranteed on all our CNC tooling solutions www techniksusa com MSDS Sheets for CIMTEC Coolant ...
Страница 30: ...30 Phone 800 597 3921 or 317 803 8000 Fax 317 803 8001 MSDS Sheets for CIMTEC Coolant ...
Страница 31: ...31 Satisfaction guaranteed on all our CNC tooling solutions www techniksusa com MSDS Sheets for CIMTEC Coolant ...
Страница 32: ...32 Phone 800 597 3921 or 317 803 8000 Fax 317 803 8001 MSDS Sheets for CIMTEC Coolant ...