18
Mounting possibilities On-/Off-sensor
Too short cables can be extended locally or ordered in a new length from us. Check following points when
extending the cables locally:
-
Use the correct cross-section!
-
Plugs and connections must correspond to the requirements.
-
Plugs and connections must be mounted correct (No free wires, good isolation)
-
Damages because of plugs and extensions mounted by the customer are NO warranty claim!
8
Configuration plug:
Electric fan
Nr. 54:
Blue cable
(– from relay)
Nr. 58L:
Brown cable (+ from relay)
Nr. 31:
Cable No. 1 (– from the unit)
Nr. 58R:
Cable No. 2 (+ from the unit)
Hydraulic fan
Nr. 54:
Nr. 58L:
Nr. 31:
Cable No. 1 (– from the unit)
Nr. 58R:
Cable No. 2 (+ from the unit)
58L
31
54
58R
9
Electric/Hydraulic fan
Cable No. 1 = minus
Cable Nr. 2 = plus
30A fuse for electric fan used in the cable to battery plus
15A fuse for hydraulic fan used in the cable to battery plus
10
Configuration socket:
Electric/Hydraulic fan
Nr. 54
to minus
Nr. 58 L
to plus
Nr. 31
to minus
Nr. 58 R
to plus
11
Configuration socket:
Electric fan
Nr. 1
LED
Nr. 2
Seed roll motor +
Nr. 3
Seed roll motor -
Nr. 4
Relay +
Nr. 5
Relay -
Configuration socket:
Hydraulic fan
Nr. 1
LED
Nr. 2
Seed roll motor +
Nr. 3
Seed roll motor -
Nr. 4
Nr. 5