![Technicolor COM1000 Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/technicolor/com1000/com1000_integrators-manual_1068007061.webp)
61
Following is a detailed list of the information available on the
HealthInfo
page.
Chassis
– This field reports a unique identifier for the chassis. In systems that contain multiple
chassis, this can be used to identify each card in the system. See
Section 4.1
unique identifiers to multiple chassis within a system.
Slot
– This field identifies the card‟s location within a chassis, numbered 1 through 12.
CardIP –
This field shows the IP address of the COM24 card that resides in the chassis and slot
combination to its left.
Card_Temperature
– This field reports the temperature of the COM24 card, as measured on its
surface. This essentially gives the ambient temperature inside the COM200 chassis.
IC_Temperature
– This field reports the internal temperature of the main processor chip on the
COM24 card. An elevated temperature here and nowhere else could mean that this chip is
defective.
PS0 Health
– This field reports the health for Power Supply 0. If the power supply is connected
and operating properly, the value should return “OK”. If there is a problem with either of these
things, the value will return “Fault”.
Note: Newer chassis will only have a single power supply instead of a dual power supply. These
power supplies do not provide health indicators so the PS0 and PS1 Health indicators will report
Fault, which should be ignored.
*See device labeled
“AC Input 1”
in
in
Section 3.2
PS1 Health
– This field reports the health for Power Supply 1. If the power supply is connected
and operating properly, the value should return “OK”. If there is a problem with either of these
things, the value will return “Fault”.
*See device labeled
“AC Input 2”
in
in
Section 3.2
Fan0 Health
– This field reports the health for Fan 0. If the fan is connected and operating
properly, the value should return “OK”. If there is a problem with either of these things, the
value will return “Fault”.
*See device labeled
“Exhaust Fan 1”
in
in
Section 3.2
Fan1 Health
– This field reports the health for Fan 1. If the fan is connected and operating
properly, the value should return “OK”. If there is a problem with either of these things, the
value will return “Fault”.
Содержание COM1000
Страница 1: ...REV 2 72 DIRECTV COM1000 Integrator s Manual Software Version ST02 08 07 ...
Страница 8: ...8 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 9: ...9 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 16: ...16 content compression type and it will stream either MPEG 2 or MPEG 4 encoded transport streams ...
Страница 29: ...29 Figure 10 COM24FLX to SWM Module connections ...
Страница 39: ...39 Figure 17 Tftpd32 Settings Window Global Settings ...
Страница 40: ...40 Figure 18 Tftpd32 Settings Window TFTP Settings ...
Страница 45: ...45 Figure 24 Discover Page w COM24FLX ...
Страница 62: ...62 See device labeled Exhaust Fan 2 in Figure 3 in Section 3 2 ...
Страница 88: ...88 Figure 46 COM1000 EPG Page Configured ...
Страница 102: ...102 The results of the upgrade in Figure 55 is shown in Figure 56 Figure 56 Multi card COM24 SW Upgrade Results ...
Страница 106: ...106 Figure 59 shows the results of starting a QAM24 SW upgrade Figure 59 QAM24 SW Upgrade Results ...
Страница 111: ...111 The directory path and filename do not exceed the maximum limit of 200 characters ...
Страница 129: ......