Feature List
The Technica Engineering 100BaseT1_SPY samples data Frames directly on the bus without influence
of the original network. The data Frames are enhanced with additional information as an exact
timestamp and the bus port the data was originally sent on. All data can be recorded on a PC or
datalogger for detailed offline analysis.
Timestamps are in 0.04 μs resolution and synchronous to all connected lines.
Optionally other UseCases (Frame Generator, Fault Injection, Data Manipulation, Trigger Generator,
… ) can be upgraded.
Features:
12x BroadR-Reach Ports Fullduplex 100 Mbit/s
1x FlexRay Channel A (option for transmission of StartUp & Sync Frames)
5x CAN / CAN-FD Ports
1x LIN, 1x SMA Trigger
4x Gigabit Ethernet Ports for Logging data output
1x Fast Ethernet Port for status output, configuration and webserver access
1x SD Card for configuration and storage of trigger events
Stainless steel case
Power requirement:
12 Volt DC Nominal (7-16 Volt)
Power consumption:
10 Watt
Size:
147 x 124 x 26mm
Weight:
0,9 kg
International Protection:
IP 2 0
Operating Temperature:
-40 to +80 °Celsius