Care and Cleaning (continued)

1.

Remove the screw on each side out of the latch using a
screwdriver.

2.

Press on the two latches of the air intake grille with your thumbs
in the direction of the arrow to open the grille.

3.

Open the air intake grille downward.

4.

Remove the air filter from the air intake grille.

5.

Use a vacuum cleaner to remove light dust. If there is sticky
dust on the filter, wash the filter in lukewarm, soapy water, rinse
it in clean water, and dry it.

3.

Insert the filter correctly again inside the grille, close the grille
letting the latches slide toward the outside and fix again the
latch with the screw on both sides.

AIR FILTER

The air filter should be cleaned at least once every six months or
more frequently; it depends on the real operation conditions.

L A T C H

S C R E W

AIR INTAKE GRILLE

AIR FILTER

HOW TO REMOVE THE AIR INTAKE GRILLE

G R I L L E

STRING

1.

Detach the safety string from the frame (remember to attach it
again after cleaning or maintenance).

2.

Open the air intake grille, hold it on and pull it toward you to
detach the two guides.

3.

Clean the grille gently using a soft sponge, or the like. Then
dry it with care.
Neutral detergent may be used to remove stubborn dirt. Then
rinse thoroughly with water and dry it.

ADDITIONAL MAINTENANCE

The inspection or replacement of internal components involve
the removal of the condensate drain pan.

Some metal edges and the vanes of heat exchanger are sharp and
may cause injury if handled improperly; be especially careful when
you clean these parts.

CAUTION

HOW TO REMOVE THE CONDENSATE DRAIN PAN

RUBBER CORK

CONNECTORS

CONDENSATE DRAIN PAN

CLIPS (2)

SUPPORT
PLATE (2)

SCREW (4)

SPECIAL SCREW (4)

1.

Open the air intake grille.

2.

Drain the condensate water into a bucket  trough the rubber
cork that should be soon closed.

3.

Remove the frame-grille assembly by loosening the four special
screws with washer; you can utilise the two clips that fix the
frame to the unit.

4.

Disconnect the electrical connectors between the frame-grille
assembly and the unit.

5.

Remove the four screws of the two support plates.

6.

Grasp the two support plates, remove with care the condensate
drain pan and clean it inside, if necessary.

7.

Once finished the maintenance, reassemble the pan, aligning
the side with the hole for condensate drain and the side with the
pump; insert the connectors of the unit into the proper hole in
the pan.

8.

Fix again the four screws of the support plates and the frame

group aligning the corner from which the wires exit and the
corner with the connectors of the unit.

9.

Mount the air intake grille along with the filter; be sure that the

safety string has been attached and that the latch screw has
been fixed on both sides.

24

Содержание CAF124MR5IAA

Страница 1: ...Split air conditioner system Climatiseurs split Split klimager t Condizionatore d aria split system Acondicionador de aire de consola partida sistema split OPERATING INSTRUCTIONS NOTICE D UTILISATION...

Страница 2: ...ting of the room temperature thermostat allowing you to set the temperature at whatever level that you find comfortable Automatic and 3 step Fan Speed Auto High Medium Low Air Sweep Control This funct...

Страница 3: ...serial numbers are on the nameplate on the bottom of the cabinet Model No ______________________ Serial No _________________________ Date of purchase __________________________________________________...

Страница 4: ...hrough the supply wiring 3 Wiring must be done by a qualified electrician Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficultie...

Страница 5: ...ner will be set by the detected temperature 13 Operation selector ON Position In this position the air conditioner is operating and controlled by the remote control unit Set the selector normally in t...

Страница 6: ...OR DRY COOL 2 Confirmation of transmission 3 Set temperature 16 30 C When set to 28 C Current temperature indication 4 Timer ON Timer OFF Timer 1 hour OFF Timer Remote Control Unit Display Displayed w...

Страница 7: ...ON OFF operation button This button is for turning the air conditioner on and off When you press this button regardless of whether the unit is operating or stopping the unit operates for one hour and...

Страница 8: ...DRY The air conditioner reduces the humidity in the room COOL The air conditioner makes the room cooler FLAP button Press this button either to select the setting of the airflow direction to the auto...

Страница 9: ...eiving tone beep is heard from the indoor unit Normally the tabs on the remote control unit should not be bent A C SENSOR button When you press this button use a small tipped object such as a ballpoin...

Страница 10: ...he batteries when the remote control unit s display fails to indicate or when the remote control cannot be used to change the air conditioner s settings Use two fresh leak proof type AAA alkaline batt...

Страница 11: ...eed and airflow direction Each time one of the temperature setting buttons TEMP is pressed the temperature is changed by 1 C The temperature can be changed from 4 C higher to 4 C lower from the standa...

Страница 12: ...tion and fan speed can be changed to suit your individual preference It will take a few seconds for the fan speed to be switched 2 Manual Operation NOTE Check that the circuit breaker on the power pan...

Страница 13: ...er than the current room temperature and perform the drying operation NOTE This appliance has a built in 3 minute time delay circuit to ensure reliable operation When the operation button is pressed t...

Страница 14: ...lly during operation just set the FAN SPEED selector button as desired or 4 ECONOMY Mode The ECONOMY Mode is used for saving energy Press the ECONOMY button while the air conditioner is operating The...

Страница 15: ...tting 3 C when 60 minutes have passed after the selection was made and then another 4 C after another 2 hours have passed regardless of the indoor temperature when ECONOMY was selected This enables yo...

Страница 16: ...the unit again Clicking Sound Clicking sound is heard from the air conditioner In heating or cooling operation any plastic parts may expand or shrink due to a sudden temperature change In this event...

Страница 17: ...he time rapidly in 10 minute increments This completes the setting of the current time 2 How to set the OFF time Example To stop the air conditioner at 11 00 am 1 Press the OFFTIME setting button once...

Страница 18: ...en the ON timer is used the temperature setting may not be reached by the set time depending on the size and conditions in the room To cancel a timer program Press the CANCEL button When either an ON...

Страница 19: ...d 3 1 2 3 Indication The present time 10 30 pm and are displayed OFF time Present time ON time Daily ON OFF NOTE The ON OFF combination timer uses the current time as the reference and it is activated...

Страница 20: ...r Whichever function is set last takes precedence If the 1 HR TIMER button is pressed while theTIMER OFF function operates the OFF Timer is cancelled and the unit will stop operating one hour later 2...

Страница 21: ...y for 15 minutes the temperature setting has been reached during a cooling or heating operation or the humidity setting has been reached during a drying operation which is only when one indoor unit is...

Страница 22: ...the air warms up the flap position and fan speed change to the settings specified with the remote control Use the FLAP button on the remote control to adjust the position of the flap If you move the...

Страница 23: ...rvice center Operation without the Remote Control Unit If you have lost the remote control unit or it has trouble follow the steps below 1 When the air conditioner is not running If you want to turn o...

Страница 24: ...NAL MAINTENANCE The inspection or replacement of internal components involve the removal of the condensate drain pan Some metal edges and the vanes of heat exchanger are sharp and may cause injury if...

Страница 25: ...e it to ensure good airflow 5 Set the temperature lower or higher 6 Consult your dealer or try to use a back up heater This is normal and the sound will soon disappear 1 Turn off the power then restar...

Страница 26: ...en auf die Umwelt und die menschliche Gesundheit die durch eine nicht vorschrichtsm ige Entsorgung bedingt ist Zudem erm glicht wird die Wiederverwertung der Materialen aus denen sich das Ger t zusamm...

Страница 27: ...ut prior notice Per garantire un costante miglioramento dei nostri prodotti ci riserviamo di modificarli senza preavviso Par souci d am lioration constante nos produits peuvent tre modifi s sans pr av...

Отзывы: