5-4. Air conditioner operates, but abnormalities are observed
5-4-1. Operation does not switch from HEAT to COOL (or COOL to HEAT)
Remote control unit
Receiver in lamp ass'y
may be defective
may be defective
Measure resistance of
4-way valve's winding
COOL to HEAT
Check voltage between
Outdoor PCB ass'y is defective
terminals N and 6 (230V AC)
Indoor PCB ass'y is defective
HEAT to COOL
Check voltage between
terminals N and 6 (230V AC)
OK
No voltage appears
27