![Technibel Climatisation 387106979 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/technibel-climatisation/387106979/387106979_technical-data-and-service-manual_1067693025.webp)
5
-3. Some part of air conditioner does not operate.
5
-3-1. Only indoor fan does not run.
5
-3-2. Only flap motor does not run.
5
-3-3. Only outdoor fan does not run.
Fan cannot
be turned.
OK
• Check fan rotation.
Turn fan gently once or twice by
hand.
• Check fan casing
foreign matter on
inside.
Fan motor burnout
or foreign matter in
bearings.
Remove foreign
matter or repair.
Repair or replace.
• Measure resistance of outdoor fan
motor winding.
• Check fan motor capacitor.
• Measure resistance of flap motor
winding.
Fan cannot
be turned.
OK
• Check fan rotation.
Turn fan gently once or twice by
hand.
• Check fan casing
foreign matter on
inside.
Fan motor burnout
or foreign matter in
bearings.
Remove foreign
matter or repair.
Repair or replace.
• Measure resistance of indoor fan
motor winding.
• Check fan motor capacitor.
PCB assy is defective.
OK
5-3-2
25
Содержание 387106979
Страница 8: ...2 DIMENSIONAL DATA Units mm 8...
Страница 9: ...3 ELECTRICAL DATA 3 1 Electric Wiring Diagrams 9...
Страница 10: ...4 1 Cool Mode Operation 4 FUNCTION 10...
Страница 11: ...4 2 Heat Mode Operation 11...
Страница 12: ...4 3 Auto Cool Heat Mode Operation 12...
Страница 13: ...4 4 Dry Mode Operation 13...
Страница 15: ...2 Outdoor Coil High Pressure Protection 15...
Страница 16: ...4 7 Protection Operations in Heat Mode 1 Outdoor Coil Deice Protection 16...
Страница 17: ...17...
Страница 18: ...2 Indoor Coil High Pressure Protection in Heat Mode 18...
Страница 19: ...4 8 Sleep Function 4 9 Daily Timer Function 4 10 IFEEL Function 19...